Terminal Wiring Cross Reference
Original Control
Replacement Control
Honeywell
Robertshaw
Old White-Rodgers
Terminal Function
S89 / S890 Terminal
HS780 Terminal
50E / F47 Terminal
50E47-843
Burner Ground Connection
GND (BURNER)
a
TR (GND CLIP)
b
GND
GND
Transformer Secondary
24V (GND)
a
GND
TR
TR
(unswitched leg)
Main Valve Common
VALVE (GND)
a
—
c
MV
a
(next to
MV2
TR terminal)
Transformer Secondary
24V
a
TH
TH
TH
(switched leg)
Main Valve Operator
VALVE
VALVE
d
MV
d
MV1
120 Vac Neutral Leg
L2 120V NEUTRAL
L2
—
L2
e
Power Supply
120 Vac Hot Leg
L1 120V HOT
L1
L
f
L1 120V HOT
Power Supply
Hot Surface Igniter Element
HSI 120V
IGN
—
HS2
Hot Surface Igniter Element
HSI 120V
IGN
IGN
g
HSI
Flame Sensor
SEN
h
RS
h
FP
i
FP
h
a
Remove quick-connect and replace with the included 1/4” quick-connect.
b
Use green adapter cable (provided) to connect terminal to chassis ground.
c
Do not use the MV2 terminal. MV2 and TR are interconnected in the appliance wiring.
d
Remove quick-connect and replace with the included 3/16” quick-connect.
e
Ground this terminal using green adapter cable if model being replaced does not have 120V neutral power supply connec-
tion.
f
Use the red wire on the included adapter cable.
g
Use the blue wire on the included adapter cable.
h
On indirect sense models, remove jumper quick-connect from FP terminal, cut jumper wire at circuit board and discard.
On direct sense models, jumper connected to FP terminal, see figure 4.
i
Remove jumper from FP terminal, cut jumper wire at circuit board and discard.
M
V
2
T
R
G
N
D
T
H
M
V
1
L
2
F
P
L
1
H
S
1
THERMOSTAT OR
CONTROLLER
ALTERNATE
LIMIT
L1
(HOT)
L2
LIMIT
CONTROLLER
FLAME
PROBE
RED
ADAPTER
BLUE
HOT
SURFACE
IGNITER
MV
MV
GAS
VALVE
BURNER
GROUND
H
S
2
TRANSFORMER
JUMPER
(clip)
M
V
2
T
R
G
N
D
T
H
L
2
F
P
THERMOSTAT OR
CONTROLLER
ALTERNATE
LIMIT
L1
(HOT)
L2
LIMIT
CONTROLLER
MV
MV
GAS
VALVE
BURNER
GROUND
HOT
SURFACE
IGNITER
H
S
2
FLAME
PROBE
L
1
M
V
1
H
S
1
TRANSFORMER
JUMPER
(clip)
Fig. 1 – Typical hookup for White-Rodgers replacement
with indirect sense using flame probe
Fig. 3 – Typical hookup for competitive replacement with
indirect sense using flame probe
Fig. 4 – Program Key installation/Jump-
er for models with indirect sense clip
jumper
Program Keys
M
V
2
T
R
G
N
D
T
H
L
2
F
P
THERMOSTAT OR
CONTROLLER
ALTERNATE
LIMIT
L1
(HOT)
L2
LIMIT
CONTROLLER
MV
MV
GAS
VALVE
BURNER
GROUND
HOT
SURFACE
IGNITER
H
S
2
FLAME
PROBE
L
1
M
V
1
H
S
1
TRANSFORMER
JUMPER
Fig. 2 – Typical hookup for competitive
replacement with direct flame sense
through ignitor
Jumper
Select and insert the correct program key to match the application.
WIRING
50E47-843
L2 must be grounded
www.white-rodgers.com187