Background Image
Previous Page  186 / 221 Next Page
Information
Show Menu
Previous Page 186 / 221 Next Page
Page Background

Terminal Wiring Cross Reference

Original Control

Replacement Control

Honeywell

Robertshaw

Old White-Rodgers

Terminal Function

S89 / S890 Terminal

HS780 Terminal

50E / F47 Terminal

50E47-843

Burner Ground Connection

GND (BURNER)

a

TR (GND CLIP)

b

GND

GND

Transformer Secondary

24V (GND)

a

GND

TR

TR

(unswitched leg)

Main Valve Common

VALVE (GND)

a

c

MV

a

(next to

MV2

TR terminal)

Transformer Secondary

24V

a

TH

TH

TH

(switched leg)

Main Valve Operator

VALVE

VALVE

d

MV

d

MV1

120 Vac Neutral Leg

L2 120V NEUTRAL

L2

L2

e

Power Supply

120 Vac Hot Leg

L1 120V HOT

L1

L

f

L1 120V HOT

Power Supply

Hot Surface Igniter Element

HSI 120V

IGN

HS2

Hot Surface Igniter Element

HSI 120V

IGN

IGN

g

HSI

Flame Sensor

SEN

h

RS

h

FP

i

FP

h

a

Remove quick-connect and replace with the included 1/4” quick-connect.

b

Use green adapter cable (provided) to connect terminal to chassis ground.

c

Do not use the MV2 terminal. MV2 and TR are interconnected in the appliance wiring.

d

Remove quick-connect and replace with the included 3/16” quick-connect.

e

Ground this terminal using green adapter cable if model being replaced does not have 120V neutral power supply connec-

tion.

f

Use the red wire on the included adapter cable.

g

Use the blue wire on the included adapter cable.

h

On indirect sense models, remove jumper quick-connect from FP terminal, cut jumper wire at circuit board and discard.

On direct sense models, jumper connected to FP terminal, see figure 4.

i

Remove jumper from FP terminal, cut jumper wire at circuit board and discard.

M

V

2

T

R

G

N

D

T

H

M

V

1

L

2

F

P

L

1

H

S

1

THERMOSTAT OR

CONTROLLER

ALTERNATE

LIMIT

L1

(HOT)

L2

LIMIT

CONTROLLER

FLAME

PROBE

RED

ADAPTER

BLUE

HOT

SURFACE

IGNITER

MV

MV

GAS

VALVE

BURNER

GROUND

H

S

2

TRANSFORMER

JUMPER

(clip)

M

V

2

T

R

G

N

D

T

H

L

2

F

P

THERMOSTAT OR

CONTROLLER

ALTERNATE

LIMIT

L1

(HOT)

L2

LIMIT

CONTROLLER

MV

MV

GAS

VALVE

BURNER

GROUND

HOT

SURFACE

IGNITER

H

S

2

FLAME

PROBE

L

1

M

V

1

H

S

1

TRANSFORMER

JUMPER

(clip)

Fig. 1 – Typical hookup for White-Rodgers replacement

with indirect sense using flame probe

Fig. 3 – Typical hookup for competitive replacement with

indirect sense using flame probe

Fig. 4 – Program Key installation/Jump-

er for models with indirect sense clip

jumper

Program Keys

M

V

2

T

R

G

N

D

T

H

L

2

F

P

THERMOSTAT OR

CONTROLLER

ALTERNATE

LIMIT

L1

(HOT)

L2

LIMIT

CONTROLLER

MV

MV

GAS

VALVE

BURNER

GROUND

HOT

SURFACE

IGNITER

H

S

2

FLAME

PROBE

L

1

M

V

1

H

S

1

TRANSFORMER

JUMPER

Fig. 2 – Typical hookup for competitive

replacement with direct flame sense

through ignitor

Jumper

Select and insert the correct program key to match the application.

WIRING

50E47-843

L2 must be grounded

www.white-rodgers.com

187

TECHNICAL HELP