OPERATION

AND TROUBLESHOOTING

50E47-843

M

V

2

T

R

G

N

D

T

H

M

V

1

L

2

F

P

L

1

H

S

1

THERMOSTAT OR

CONTROLLER

ALTERNATE

LIMIT

L1

(HOT)

L2

LIMIT

CONTROLLER

FLAME

PROBE

RED

ADAPTER

BLUE

HOT

SURFACE

IGNITER

MV

MV

GAS

VALVE

BURNER

GROUND

H

S

2

TRANSFORMER

JUMPER

(clip)

YELLOW FLASHING INDICATOR: IMPROPER POLARITY LOCKOUT

RED SOLID INDICATOR LIGHT: INTERNAL FAULT OR REVERSED CONNECTIONS AT GAS VALVE

YELLOW FLASHING INDICATOR (IMPROPER POLARITY LOCKOUT):

Yellow indicator will flash if the polarity is not correct

as diagrammed above on both the primary and secondary of the system transformer.

To check the polarity on the primary of the transformer it can be tested at the module. The L1 terminal on the module should

be 120 volts (Hot) and should measure 120 volts to GND.

To check the secondary of the transformer, module terminal L1 should measure approximately 95 volts to TH. If the reading

is approximately 120 to 150 volts the secondary is not phased correctly. To correct this condition, reverse the secondary wires

on the system transformer. Note: TR on this module is tied to GND. Some systems may have more than one ground. When

you reverse the 24 volt secondary be sure that only the TR and GND leads are grounded.

RED SOLID INDICATOR LIGHT (INTERNAL FAULT OR REVERSED CONNECTIONS AT GAS VALVE):

A solid red indicator

light means internal module fault or reversed connections at the gas valve. Before replacing the module, reverse

low voltage connections to gas valve.

At installation, this module has a self-test and requires all system components (Transformer, Ignitor, Gas Valve and Flame

Sensor) to be attached and turned on for it to operate. Gas valves with an Electric “On/Off” switch must be turned “ON”. A

lockout condition on this control during self-test will not damage equipment or the control.

* NOTE:

Ground this terminal if model being replaced does not have 120V neutral

*

www.white-rodgers.com

188

TECHNICAL HELP