INSTALLER/CONFIGURATION MENU
To enter the menu: Press the
Menu
touch key. Press and hold for 5 seconds the
Installer Config
touch key. This displays
menu item #1 in the table below. Press to advance to the next menu item or to return to a previous menu item. Press
or to change a menu item.
CONFIGURATION MENU
Menu
Reference
Numbe
r
Program-
mable
Non-Pro-
grammable
Press
key
Displayed
Factory
(Default)
Press or
to select from
listed options
COMMENTS
1
1
1
(ELE)
GAS
GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
2
2
2
(
7
) Days,
P
5
-1-1 or
0
Programs per week. (0 = non-programmable)
3
3
NA
(
4
)
PS
2
Program periods per day.
4 = Morning, Day, Evening, Night
2 = Day, Night
4
4
3
Cool-Off-
Heat-Auto
Cool-Off-Heat,
Off-Heat, Cool-Off
System switch configuration.
5
5
NA
(On)
E
OFF
Selects Energy Management Recovery, E (with programming
option on)
6
6
4
(FA) Heat, Cr
SL
Selects Adjustable Anticipation, cycle rate, Heat
7
7
5
(FA) Cool, Cr
SL
Selects Adjustable Anticipation, cycle rate, Cool
8
8
6
(OFF)
CL
On
Selects Compressor Lockout.
9
9
7
(On)
dL
OFF
Selects Continuous Display backlight & intensity.
10
10
8
(LO)
dL
HI
Selects Backlight Intensity.
11
11
9
0
(temperature)
4, LO to 4, HI
Selects Adjustable Ambient Temperature Display [range -4 (LO)
to +4 (HI)].
12
12
10
°
F
°
C
Selects °F/°C Display (temperature units in Fahrenheit or Celsius).
13
13
11
(On)
b
OFF
Selects audible Beeper On/Off.
14
14
12
(On)
dS
OFF
Selects Daylight Saving Time calculation.
15
15
13
(On) Heat,
AS
OFF
Selects Automatic Schedule for comfort temperature Program-
ming, heat mode.
16
16
14
(On) Cool,
AS
OFF
Selects Automatic Schedule for comfort temperature Program-
ming, cool mode.
17
17
15
(OFF)
CS
,
Cool Savings
1-2-3-4-5-6
Selects Cool Saving Feature & amount.
18
18
16
(99) Heat,
HL
62-98
TEMPERATURE LIMIT, HEAT (max. heat set point).
19
19
17
(45) Cool,
LL
46-82
TEMPERATURE LIMIT, COOL (min. cool set point).
20
20
18
OFF,
Keypad Lockout
L
(total),
P
(partial),
Temperature Limit
(limited temperature range)
Selects Keypad Lockout.
000
001-999
Selects Keypad Lockout Combination (active only if keypad
Lockout is selected).
21
21
19
(OFF) Remote
On
Remote temperature sensor, enable/disable.
Remote, In
Outdoor Remote Remote temperature sensor (Indoor/Outdoor).
(On) LS
OFF
Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
22
22
20
Change Filter
(OFF)
On
Selects Change filter feature
200 Hours
25-1975 (in increments
of 25 hours)
Change filter, duration hours.
1F97-1277
CONFIGURATION
www.white-rodgers.com132
TECHNICAL HELP