CONFIGURATION
1F95-1280/1F95-1291
1F95-1280 INSTALLER/CONFIGURATION MENU (cont.)
To enter the menu: Press the
Menu
touch key. Press and hold for 5 seconds the
Installer Config
touch key. This displays
menu item #1 in the table below. Press to advance to the next menu item or to return to a previous menu item. Press
or to change a menu item option.
1F95-1291 INSTALLER/CONFIGURATION MENU
CONFIGURATION MENU
Menu
Reference
Numbe
r
Program-
mable
Non-
Program-
mable
Press
key
Displayed
Factory
(Default)
Press or
to select from
listed options
COMMENTS
1
1
1
MS 2
HP 1, HP 2, SS 1
Selects Multi-Stage (MS2, No Heat Pump), Heat Pump 1
(HP1, 1 compressor), Heat Pump 2 (HP2, 2 compressor
or 2 speed compressor), or Single Stage.
2
2
2
GAS
(ELE)
GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
3
3
3
ob (O)
b
Selects Reversing Valve (This item is only to appear if HP1 or HP2 is
selected above.)
4
4
3
(7)
Days,
P
5
or
0
Programs per week. (5=5-1-1 or 0 = non-programmable)
5
5
NA
(4) PS
2
Programs per day.
4 = Morning, Day, Evening, Night
2 = Day, Night
6
6
4
Cool-Off-
Heat-Auto
Cool-Off-Heat, Heat Off,
Heat, Cool-Off, Auto Off
System switch configuration in non heat pump mode.
Cool-Off-Heat-
Em-Auto
Cool-Off-Heat-Em,
Off-Em-Auto
System switch configuration, heat pump mode.
7
7
NA
(On)
E
OFF
Selects Energy Management Recovery, E (with programming option
on)
8
8
5
(FA) Heat, Cr
SL
Selects Adjustable Anticipation, cycle rate, Heat
9
9
6
(FA) Cool, Cr
SL
Selects Adjustable Anticipation, cycle rate, Cool
10
10
7
Cr/AU, Em (FA)
SL
Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP1 or HP2 is selected above).
11
11
8
(OFF)
CL
On
Selects Compressor Lockout.
12
12
9
(On)
dL
OFF
Selects Continuous Display backlight.
13
13
10
(LO)
dL
HI
Selects Backlight Intensity.
14
14
11
0
(temperature)
5, LO to 5, HI
Selects Adjustable Ambient Temperature Display [range -5 (LO) to
+5 (HI)].
15
15
12
°F
(temperature)
°C
Selects °F/°C Display (temperature units in Fahrenheit or Celsius).
16
16
13
(On)
b
OFF
Selects audible Beeper On/Off.
CONFIGURATION MENU
Menu
Reference
Numbe
r
Program-
mable
Non-
Program-
mable
Press
key
Displayed
Factory
(Default)
Press or
to select from
listed options
COMMENTS
28
(cont.)
28
(cont.)
26
(cont.)
(OFF) dF
On
Selects Dual Fuel feature using outdoor sensor On or OFF (This item
appears if HP1 or HP2 is selected and outdoor sensor is installed and
enabled.
28
28
26
(35) dF
5-50
Selects Dual Fuel setpoint (°F) with outdoor sensor available.
(60) Cd
0-99
Selects compressor delay in seconds.
29
29
27
(80) AO
35-74
Selects Auxiliary Heat cut out temperature. This item appears if HP1
or HP2 is selected and outdoor sensor is installed and enabled.
30
30
28
(80) bP
79-20
Not used
31
31
NA
(o) PP
1, 2, 3
Select Pre-occupancy purge.
32
32
NA
(OFF) EC
ON
Select Economizer or Damper Operation (default)
33
33
29
(OFF) Change
UV Lamp
On
Selects Change UV Lamp feature.
350 Days
25-1975
Change UV Lamp duration days.
34
34
30
OFF
Change Filter
On
Selects Change Filter feature.
200 Hrs
25-1975
Change Filter duration hours.
www.white-rodgers.com135