1F95-1291 INSTALLER/CONFIGURATION MENU (cont.)
1F95-1291
CONFIGURATION
CONFIGURATION MENU
Menu
Reference
Numbe
r
Program-
mable
Non-
Program-
mable
Press
key
Displayed
Factory
(Default)
Press or
to select from
listed options
COMMENTS
17
17
14
(On)
dS
OFF
Selects Daylight Saving Time calculation.
18
18
15
(Off) Heat,
AS
On
Selects Automatic Schedule for comfort temperature Programming,
heat mode.
19
19
16
(On) Cool,
AS
OFF
Selects Automatic Schedule for comfort temperature Programming,
cool mode.
20
20
17
(OFF)
CS
On
Selects Cool Savings Feature On of Off.
CS
Cool Savings
(3)
1-2-3-4-5-6
Selects amount of Cool Savings adjustment.
21
21
18
(Off)
CO
On
Select Compressor Optimization (not available on earlier models)
22
22
19
(99) Heat,
HL
62-98
TEMPERATURE LIMIT, HEAT (max. heat set point).
23
23
20
(45) Cool,
LL
46-82
TEMPERATURE LIMIT, COOL (min. cool set point).
24
24
21
OFF,
Keypad Lockout
L
(total),
P
(partial),
Temperature Limit
(limited temperature range)
Selects Keypad Lockout.
000
001-999
Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
25
25
22
(On) Heat, FS
OFF
Fast second stage of heat (not available if SS1 is selected above).
26
26
23
(On) Cool, FS
OFF
Fast second stage of cool (not available if SS1 or HP1 is selected
above).
27
27
24
Remote (OFF)
On
Remote temperature sensor, enable/disable.
Remote, In
Outdoor Remote
Remote temperature sensor (Indoor/Outdoor).
(On) LS
OFF
Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
28
28
25
(OFF) dF
On
Selects Dual Fuel feature using software logic On or OFF (This item
appears if HP1 or HP2 is selected above and no outdoor sensor.
(05) dF
0-09
Selects Dual Fuel setpoint (°F) with no outdoor sensor.
(60) Cd
0-99
Selects compressor delay in seconds.
29
29
26
(OFF) dF
On
Selects Dual Fuel feature using outdoor sensor On or OFF (This item
appears if HP1 or HP2 is selected and outdoor sensor is installed and
enabled.
dF (35)
5-50
Selects Dual Fuel setpoint (°F) with outdoor sensor available.
Cd (60)
0-99
Selects compressor delay in seconds.
30
30
27
AO (80)
35-74
Selects Auxiliary Heat cut out temperature. This item appears if HP1
or HP2 is selected and outdoor sensor is installed and enabled.
31
31
28
bP (80)
79-20
Selects Blower balance point. Selection of 80 disables this feature.
This item appears if HP1 or HP2 is selected and outdoor sensor is
installed and enabled.
32
32
29
Hd (OFF)
on
Selects Humidity Display alternate with time.
33
33
30
Humidity
H1, OD
-20-20-18
Selects Humidity Display adjustment.
34
34
31
HR (OFF)
LO, HI
Selects Auto Humidity reduction.
35
35
32
AH (OFF)
H, C, A
Selects Automatic Humidification.
36
36
33
CH (OFF)
On
Selects Cycle Humidifier.
37
37
34
OC (o)
od, OFF
Selects Optimum Comfort or Optimum Dehumidification.
38
38
35
Change UV
Lamp (OFF)
On
Selects Change UV Lamp feature.
350 Days
25-1975
Change UV Lamp duration days.
39
39
36
Change Pad
(OFF)
On
Selects Change Humidifier Pad feature.
1000 Hrs
25-1975
Change Humidifier Pad duration hours.
40
40
37
OFF
Change Filter
On
Selects Change Filter feature.
200 Hrs
25-1975
Change Filter duration hours.
www.white-rodgers.com136
TECHNICAL HELP