1F95-1291 INSTALLER/CONFIGURATION MENU (cont.)

1F95-1291

CONFIGURATION

CONFIGURATION MENU

Menu

Reference

Numbe

r

Program-

mable

Non-

Program-

mable

Press

key

Displayed

Factory

(Default)

Press or

to select from

listed options

COMMENTS

17

17

14

(On)

dS

OFF

Selects Daylight Saving Time calculation.

18

18

15

(Off) Heat,

AS

On

Selects Automatic Schedule for comfort temperature Programming,

heat mode.

19

19

16

(On) Cool,

AS

OFF

Selects Automatic Schedule for comfort temperature Programming,

cool mode.

20

20

17

(OFF)

CS

On

Selects Cool Savings Feature On of Off.

CS

Cool Savings

(3)

1-2-3-4-5-6

Selects amount of Cool Savings adjustment.

21

21

18

(Off)

CO

On

Select Compressor Optimization (not available on earlier models)

22

22

19

(99) Heat,

HL

62-98

TEMPERATURE LIMIT, HEAT (max. heat set point).

23

23

20

(45) Cool,

LL

46-82

TEMPERATURE LIMIT, COOL (min. cool set point).

24

24

21

OFF,

Keypad Lockout

L

(total),

P

(partial),

Temperature Limit

(limited temperature range)

Selects Keypad Lockout.

000

001-999

Selects Keypad Lockout Combination (active only if keypad Lockout

is selected).

25

25

22

(On) Heat, FS

OFF

Fast second stage of heat (not available if SS1 is selected above).

26

26

23

(On) Cool, FS

OFF

Fast second stage of cool (not available if SS1 or HP1 is selected

above).

27

27

24

Remote (OFF)

On

Remote temperature sensor, enable/disable.

Remote, In

Outdoor Remote

Remote temperature sensor (Indoor/Outdoor).

(On) LS

OFF

Local temp. Sensor enable/disable (only when Indoor Remote is

selected On).

28

28

25

(OFF) dF

On

Selects Dual Fuel feature using software logic On or OFF (This item

appears if HP1 or HP2 is selected above and no outdoor sensor.

(05) dF

0-09

Selects Dual Fuel setpoint (°F) with no outdoor sensor.

(60) Cd

0-99

Selects compressor delay in seconds.

29

29

26

(OFF) dF

On

Selects Dual Fuel feature using outdoor sensor On or OFF (This item

appears if HP1 or HP2 is selected and outdoor sensor is installed and

enabled.

dF (35)

5-50

Selects Dual Fuel setpoint (°F) with outdoor sensor available.

Cd (60)

0-99

Selects compressor delay in seconds.

30

30

27

AO (80)

35-74

Selects Auxiliary Heat cut out temperature. This item appears if HP1

or HP2 is selected and outdoor sensor is installed and enabled.

31

31

28

bP (80)

79-20

Selects Blower balance point. Selection of 80 disables this feature.

This item appears if HP1 or HP2 is selected and outdoor sensor is

installed and enabled.

32

32

29

Hd (OFF)

on

Selects Humidity Display alternate with time.

33

33

30

Humidity

H1, OD

-20-20-18

Selects Humidity Display adjustment.

34

34

31

HR (OFF)

LO, HI

Selects Auto Humidity reduction.

35

35

32

AH (OFF)

H, C, A

Selects Automatic Humidification.

36

36

33

CH (OFF)

On

Selects Cycle Humidifier.

37

37

34

OC (o)

od, OFF

Selects Optimum Comfort or Optimum Dehumidification.

38

38

35

Change UV

Lamp (OFF)

On

Selects Change UV Lamp feature.

350 Days

25-1975

Change UV Lamp duration days.

39

39

36

Change Pad

(OFF)

On

Selects Change Humidifier Pad feature.

1000 Hrs

25-1975

Change Humidifier Pad duration hours.

40

40

37

OFF

Change Filter

On

Selects Change Filter feature.

200 Hrs

25-1975

Change Filter duration hours.

www.white-rodgers.com