1HDEZ-1521
INSPIRE
TERMINAL
CONNECTIONS
Equipment Control
Terminals
Operation / Function
R
24 VAC Transformer
RC
24 VAC Cooling Transformer*
RH
24 VAC Heating Transformer*
C
24V Transformer Common
W/E
Heating Stage 1 HP Aux/Em Heat Stage 1
W2
Heating Stage 2 HP Aux/Em Heat Stage 2
Y
Compressor Stage 1
Y2
Compressor Stage 2
G
Fan Relay
L Terminal
System Monitor Compatible with Comfort Alert Diagnostics
O/B Terminal
Changeover Relay Heat Pump
DHM
Dehumidification Relay / Connection
DHM2
Dehumidification Relay / Connection
HM
Humidification Relay / Connection
HM2
Humidification Relay / Connection
R
Data to/from Interface
1
Data to/from Interface
2
Data to/from Interface
C
24 VAC Common to Interface
RJ11
Field configuration hook-up with RJ11
equipped configuration tool
+
Voltage to Outdoor Sensor
S
Outdoor Sensor Temperature Signal
-
Voltage to Outdoor Sensor
*For 2 transformer systems, cut and tape off one transformer. If transformer safety circuits are only in one of the systems,
remove the transformer of the system with NO safety circuits. If required, replace remaining transformer with a 75 VA Class
II transformer. After disconnecting one transformer, the two commons must be jumpered together.
To configure thermostat properly, go to
www.white-rodgers.comfor full Installation Instructions.