CONFIGURATION

1F83-0422/1F85-0422

With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will show

item #1 in the table below. Press Menu to advance to the next menu, Press

or

to change an item option. Shaded

items are not available to 1F83.

CONFIGURATION MENU

Menu

Ref

.

HP SS

Press

Button

Displayed

Factory (Default)

Press

or

to

select from listed options

COMMENTS

1 1 1 MENU

Lk (OFF)

L

Selects Keypad Lockout.

(Not available on earlier models)

MENU

0

001 to 999

Selects Keypad lockout combination number

2 2 2 MENU

(MS 2)

HP 1, SS 1

Selects Multi-Stage (MS 2 No Heat Pump),

Heat Pump 1 (HP 1, 1 compressor),

or Single Stage (SS 1)

3 3 3 MENU

(GAS) for SS or MS

(ELE) for HP

ELE

GAS setting: furnace controls the blower

ELE setting: thermostat controls the blower

4 4 4 MENU

CS (0)

(Disabled)

1, 2, 4, 5, 6

Selects Cool Savings

Value 1 (low) to 6 (high), Value 0 Disables Feature

5 5 5 MENU

E (On)

OFF

Selects Energy Management Recovery (EMR)

On or OFF.

1F85 only

6 – 6 MENU

CR Heat (ME)

SL, FA

Adjustable Anticipation:

Selects heating cycle rate for MS or SS

7 6 – MENU

CR Heat Pump

(ME)

SL, FA

Adjustable Anticipation (Heat Pump) (only

when heat pump selected in #1)

8 7 7 MENU

CR Cool (ME)

or

CR Emer (FA)

SL, FA

SL

Adjustable Anticipation: Selects the cycle rate for cooling (only

when MS 2 or SS 1 is selected in item 1.) or Selects the cycle

rate for Emergency mode and Auxiliary stage if Heat Pump is

selected in item 1.

9 8 8 MENU

CL (OFF)

CL On

Compressor Lockout Time

10 9 9 MENU

Heat Auto

Cool Off

Heat Cool Off,

Heat Off with Fan icon,

Heat Off without Fan icon

Cool Off, Auto Off

System Mode Configuration

with Automatic Changeover capability

11 10 10 MENU

dL (On)

dL OFF

Selects Display Light On or OFF

12 11 11 MENU

0

(current temperature)

1 HI, 2 HI, 3 HI, 4 HI,

1 LO, 2 LO, 3 LO, 4 LO

Adjustable Ambient Temperature Display

13 12 12 MENU

°F

°C

Selects Fahrenheit/Celsius Temperature Display

14 13 13 MENU

L Heat

(90)

L 62 to L 89

Selects Limited HEAT Range

15 14 14 MENU

L Cool (45)

L 46 to L 82

Selects Limited COOL Range

16 15 15 MENU

P3

P0, P2

Defaults for 5-1-1 programming (P3) but non-

programmable (PO) or 5-2 programming (P2)

is available on most models.

1F85 only

17 16 16 MENU

Heat AS (On)

OFF

Automatic Schedule for heat mode. 1F85 only.

NA to Cool only system.

18 17 17 MENU

Cool AS (On)

OFF

Automatic Schedule for cool mode.

1F85 only

.

NA to Heat only system.

19 18 – MENU

Heat FA (On)

OFF

Fast Heat option may be disabled by

selecting OFF. NA to SS config.

NA to Cool only system.

20 19 – MENU

Cool FA (On)

OFF

Fast Cool option may be disabled by

selecting OFF. NA to SS config.

NA to Heat only system.

21 20

MENU

CA (OFF)

On

Selects active Comfort Alert On or OFF.

Require CA II Module. (Not available on earlier models)

22 21 18 MENU

dS (On)

OFF

Selects Automatic

d

aylight

S

avings Time option

On or OFF.

1F85 only

23 22 19 MENU Change Filter (OFF)

On

Selects Filter Change-out Indicator On or OFF.

MENU Change Filter (200 h)

25-1975 h

Change Filter time in 25 hour increments. This

menu only appears if On is selected in above.

24 23 20 MENU

Cool On (o)

Heat On (b)

Selects operation of the reversing valve terminal

(O/B) output as an O or B terminal.

24 21 RUN

SCHED

Returns to Normal Operation

INSTALLER/CONFIGURATION MENU