Background Image
Previous Page  146 / 221 Next Page
Information
Show Menu
Previous Page 146 / 221 Next Page
Page Background

1F80-0471/1F86-0471

CONFIGURATION AND

TERMINAL OUTPUTS

RH

RC

W

G

Y

O/B

C

24 V for

24 V for

Heat

Fan Compressor

3-wire

24 V

Heat

Cool

Relay

Relay

Relay

zone valve Common

RH

RC

W

G

Y

O/B

C

24 V for

24 V for

Heat Relay Fan Compressor Changeover

24 V

Heat

Cool

(with jumper Relay Relay (with Relay “O” for Common

to Y)

jumper to W) Cool, “B” for

Heat

Single Stage (Gas, Oil, Electric)

Single Stage Heat Pump (No Auxiliary Heat)

CONFIGURATION MENU

Menu

Reference

Number HP SS

Press

Button

Displayed

(Factory

Default)

Press

or

to se-

lect from listed options

COMMENTS

1

1

MENU

(O) On

b On

Reversing Valve Output (SS/HP switch must

be in the Heat Pump HP position)*

2

2 1

MENU

P (2)

P 3, P 0

Selectable Programs Per Week

(For programmable thermostat only)

3

3 2

MENU

(OFF) CS

On CS

Select Cool Savings on or off

MENU

(3)

6, 5, 4, 2, 1

Selects Cool Savings value 1 (low) to 6 (high)

4

4 3

MENU

(On) E

(OFF) E

Selects Energy Management Recovery (EMR) on or off

5

4

MENU

(ME) CR Heat

FA, SL

Adjustable Anticipation (Heat) (only when

SS/HP switch is at the SS position)

6

5

MENU

(FA) CR Cool

SL

Adjustable Anticipation (Cool) (only when

SS/HP switch is at the SS position)

7

5

MENU

(FA) CR Heat Pump

SL

Adjustable Anticipation (Heat Pump)

(only when SS/HP switch is at the HP position)

8

6 6

MENU

(OFF) CL

On CL

Compressor Lockout Time

9

7 7

MENU

Auto Heat

Cool Off

Heat Cool Off,

Heat Off with Fan icon, Heat Off

without Fan icon, Cool Off,

Auto Off

System Mode Configuration

with Automatic Changeover

10

8 8

MENU

(On) L

OFF L

Selects Display Light on or off

11

9 9

MENU

0

(temperature)

1 HI, 2 HI, 3 HI, 4 HI,

1 LO, 2 LO, 3 LO, 4 LO

Adjustable Ambient Temperature Display

12

10 10 MENU

F

C

Selects Fahrenheit/Celsius Temperature Display

13

11 11

MENU

(OFF) Change Filter

On Change Filter

Selects Filter Change-out Indicator

MENU

Change Filter 200 h

25 h to 1975 h in

25-hour increment

When on, selects time in 25 hour increments

25-hour increment

14

12 12

RUN

Returns to Normal Operation

*

NOTE:

To switch thermostat to Heat Pump, place the SS/HP switch to HP and reset thermostat by pressing FAN button, up and down arrows at the same time.

With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will show

item #1 in the table below. Press Menu to advance to the next menu item. Press

or

to change a menu item option.

Shaded items are not available on 1F86.

INSTALLER/CONFIGURATION MENU

www.white-rodgers.com

147

TECHNICAL HELP