50A66-743 LENNOX NITRIDE IGNITION
INTEGRATED HSI FURNACE CONTROL
Controls Gas Valve, Ignitor, Blower, Inducer, Humidifier
and Air Cleaner
FEATURES
• Includes diagnostic indicator flash codes.
• 3 fan speeds.
• Remote flame sense.
• Humidifier and electronic air cleaner connections (optional).
SPECIFICATIONS
Input Voltage . . . . . . . . . . 25 VAC 50 / 60 Hz
Maximum Input Current @ 25 VAC . . 0.45 amp
Valve Relay . . . . . . . . . . . 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf
Ignitor Relay . . . . . . . . . . 2.0 amp @ 120 VAC 50 / 60 Hz (resistive)
Inducer Relay . . . . . . . . . . 2.2 FLA – 3.5 LRA @ 120 VAC
Circulator Relay . . . . . . . . . 14.5 FLA – 25.0 LRA @ 120 VAC
Operating Temperature Range . . . -40 to +175°F (-40 to +79°C)
Humidity Range . . . . . . . . . 5% to 93% relative humidity (non-condensing)
Model
Number
Pre-Purge
Delay Heat
Delay Cool
Auto Reset
ON
OFF
ON
OFF
50A66-743
15
45 60 / 90 / 120 / 180 2
2/45
60 minutes
50A66-743 Replaces:
Lennox
White-Rodgers
100925-01
30W25
50A66-122
100925-02
30W2501
50A66-123
100925-03
69M08
17W92
69M0801
17W9201
69M15
23W51
69M1501
23W5101
CROSS REFERENCE
LENNOX
INTEGRATED HSI MODULE
www.white-rodgers.com51