GOODMAN MULTI-SPEED
INTEGRATED HSI MODULE
50M56-743
50M56-743 GOODMAN NITRIDE IGNITION
MULTI-SPEED INTEGRATED HSI FURNACE CONTROL
Controls Gas Valve, Ignitor, Blower, Inducer and Air Cleaner.
Replaces OEM Goodman and White-Rodgers Models
FEATURES
• System diagnostic LED with fault recall.
• Multi-speed circulator.
• One or two-stage gas valve.
SPECIFICATIONS
Operating Temperature. . . . . . . . . . . . . . . . . . . -40 to 176°F
Humidity Range . . . . . . . . . . . . . . . . . . . . . . . . 5% to 93% RH (non-condensing)
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Snap in standoffs
Electrical Ratings @ 77°F (25°C)
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . 25 VAC 50 / 60 Hz
Maximum Input Current @ 30 VAC . . . . . . . . . 0.45 amp
Relay Load Ratings
Valve Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf
Ignitor Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 amp @ 120 VAC 50 / 60 Hz
Inducer Relay . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 FLA-3.5 LRA @ 120 VAC
Circulator Relay . . . . . . . . . . . . . . . . . . . . . . . . 14.5 FLA-25.0 LRA @ 120 VAC
Flame Current Requirements
Minimum current to insure flame detection. . . . 1 uA DC
Maximum current for non-detection . . . . . . . . . 0.10 uA DC
Maximum allowable leakage resistance. . . . . . 100 M ohms
Timing Spec (@ 60 Hz) maximum
Flame establishing time . . . . . . . . . . . . . . . . . . 0.8 sec
Flame failure response time . . . . . . . . . . . . . . . 2.0 seconds
NOTE
: At 50 Hz, all timing specifications should be increased by 20%.
Model
Number
Pre-Purge
Time
Heat
Delay On
Heat Delay
Off Sec.
Cool Delay
On Sec.
Cool Delay
Off Sec.
Post
Purge
50M56-743
30 seconds
30
100 / 150
6
45
25 sec
DIRECT
REPLACEMENT
CROSS REFERENCE
NOTE
: Can also use Universal Kit 50M56U-843
50M56-743 Replaces:
Goodman
White-Rodgers
0130F00006 PCBBF122
50M56-289
0130F00006S PCBBF122S
PCB00109
PCBBF132
PCBBF109
PCBBF132S
PCBBF109S
www.white-rodgers.com50
HEATING