1F82-0261/1F89-0211
CONFIGURATION
The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.
To enter the menu: Set your thermostat to OFF and press the
and
buttons simultaneously. The display will show the
first item in the configuration menu. Press RUN/HOLD to change to the next menu item or press TIME to go backwards to the
previous item in the menu. To exit the menu and return to the program operation, press PRGM. If no keys are pressed within
fifteen minutes, the thermostat will revert to normal operation.
1F82-0261 INSTALLER/CONFIGURATION MENU
1F89-0211 INSTALLER/CONFIGURATION MENU
CONFIGURATION MENU
Menu
Reference
Number
Heat
Pump
Single
Stage
Press
Key
Displayed
(Factory
Default)
Press
or
to select from listed
options
COMMENTS
1
1
1
and
HP
SS
Select Heat Pump (HP, 1 compressor) or Single Stage (SS)
2
2
2
RUN/HOLD*
CS (OFF)
On
Select Cool Savings Feature On or OFF
RUN/HOLD*
CS (3)
1, 2, 3, 4, 5, 6
If CS selected On, selects Cool Savings value
3
3
3
RUN/HOLD*
E (On)
OFF
Select Energy Management Recovery On or OFF
4
4
RUN/HOLD*
CR HE-PU
(FA)
SL
Select Adjustable Anticipation, cycle rate, Heat Pump, Heat and
Cool
4
RUN/HOLD*
CR Heat
(FA)
SL
Select Adjustable Anticipation, cycle rate,
Heat Single Stage
5
5
RUN/HOLD*
CR Aux
(FA)
SL
Select Adjustable Anticipation, cycle rate,
Heat Pump Aux Stage
5
RUN/HOLD*
CR Cool
(FA)
SL
Select Adjustable Anticipation, cycle rate, Cool Single Stage
6
6
6
RUN/HOLD*
CL (OFF)
On
Select Compressor lockout OFF or On
7
7
7
RUN/HOLD*
L (On)
OFF
Select Display Light On or OFF
8
8
8
RUN/HOLD*
Temp
(0 HI)
4 LO to
4 HI
Select temperature display adjustment higher or lower
9
9
9
RUN/HOLD*
o
F
o
C
Select
o
F /
o
C Display (temperature units in Fahrenheit or Celsius)
10
10
RUN/HOLD*
FH (On)
OFF
Select fast second stage On or OFF
11
11
10
RUN/HOLD*
Change Filter
(OFF)
On
Select filter replacement indicator OFF or On
RUN/HOLD*
Change Filter
(200 h)
25 to 1975
If Change Filter selected On, selects time interval for Change Filter
Indicator. (in 25 hour increments)
12
RUN/HOLD*
Returns to normal operation
*Press
RUN/HOLD
to advance to next item or
TIME
to move backwards to previous item
CONFIGURATION MENU
Menu
Reference
Number
Press
Key
Displayed
(Factory
Default)
Press
or
to select from listed
options
COMMENTS
1
and
CS (OFF)
On
Select Cool Savings Feature On or OFF
and
CS (3)
1, 2, 3, 4, 5, 6
If CS selected On, selects Cool Savings value
2
and
CR HE-PU
(FA)
SL
Select Adjustable Anticipation, cycle rate, Heat Pump, Heat and Cool
3
and
CR Aux (FA)
SL
Select Adjustable Anticipation, cycle rate,
Heat Pump Aux Stage
4
and
CL (OFF)
On
Select Compressor lockout OFF or On
5
and
L (On)
OFF
Select Display Light On or OFF
6
and
Temp
(0 HI)
4 LO to
4 HI
Select temperature display adjustment higher or lower
7
and
o
F
o
C
Select
o
F /
o
C Display (temperature units in Fahrenheit or Celsius)
8
and
FH (On)
OFF
Select fast second stage On or OFF
9
and
Change Filter
(OFF)
On
Select filter replacement indicator OFF or On
and
Change Filter
(200 h)
25 to 1975
If Change Filter selected On, selects time interval for Change Filter Indicator.
(in 25 hour increments)
10
and
Returns to normal operation
www.white-rodgers.com158
TECHNICAL HELP