36C Series
PARTS AND ACCESSORIES
See end of this section for parts and accessories
36C SERIES
GAS VALVES
GAS BURNER
CONTROLS
?
wiring
172–175
HSI/DSI VALVES, INTERMITTANT IGNITION
36C74-913
Step
Open
24VAC Natural
3
/
4
x
3
/
4
Step 0.9
”
/3.5
”
2.5
”
-5.0
”
No
No
No Str. Thru Yes Yes No 5
36C94-303
Intermit-
tent
Ignition
Systems
24VAC Natural
or
LP
1
/
2
x
3
/
4
Delay
Slow
3.5
”
2.5
”
-5.0
”
7.0
”
-12.0
”
Yes
Yes
No Str. Thru No Yes No 15
➀
Wiring diagrams – see pages 172–175
Indicates Canadian Model Number
U
=
Universal
36C SERIES STANDING PILOT SNAP OPEN, sTEP
oPEN, HSI, DSI, AND INTERMITTENT IGNITION
GAS VALVES
A Wide Range of Replacement Valves for the Professional Installer
SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . 0.23 amps
Ambient Operating Range . . . . . . . . -40 to +175°F (-40 to 79°C)
Maximum Pressure Rating . . . . . . . .
1
/
2
PSI (14.0
”
W.C.)
Pilot Gas Connection . . . . . . . . . .
1
/
4
”
compression fitting
Pressure Tap . . . . . . . . . . . . .
1
/
8
”
N.P.T.
Pipe Size
1” Pressure Drop Capacity
Rated Range of Regulation
BTU/HR
BTU/HR
STD. NAT GAS
1000 BTU/CU. FT.
LP GAS
2500 BTU/CU. FT.
STD. NAT GAS
1000 BTU/CU. FT.
LP GAS
2500 BTU/CU. FT.
1/2 X 3/8
100,000
162,000
15,000-100,000
15,000-162,000
1/2 X 1/2
230,000
372,600
30,000-290,000
30,000-469,000
1/2 X 3/4
230,000
372,600
30,000-290,000
30,000-469,000
3/4 X 3/4
280,000
453,600
50,000-400,000
50,000-648,000
SNAP OPEN, SINGLE FUNCTION, STANDING PILOT GAS VALVES
Model
Number
Typical
App.
Coil
Voltage
Gas
Type
Pipe
Size
Opening
Character-
istic
Regulator
Setting
Regulator
Adjustment
Range
Convertible
Nat. / LP
LP
Conversion
Kit Included
Line
Interrupter
Flow
Direction
Reducer
Bushing
Kit
Inlet
Pressure
Tap
Side
Taps
Internal
Wiring See
Figure
➀
36C01-405
Snap
Open
24VAC Natural
or
LP
3
/
4
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
No Str. Thru Yes
No No 1
36C01A-405
Snap
Open
120VAC Natural
or
LP
3
/
4
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
No Str. Thru Yes
No No 3
36C03-300
Standing
Pilot
24VAC Natural
or
LP
1
/
2
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
Yes Str. Thru Yes
No No 1
36C03-333
Standing
Pilot
24VAC Natural
or
LP
1
/
2
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
Yes Str. Thru Yes
No Yes
1
36C03-400
Standing
Pilot
24VAC Natural
or
LP
3
/
4
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
Yes Str. Thru Yes
No No 1
36C03-433
Standing
Pilot
24VAC Natural
or
LP
3
/
4
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
Yes Str. Thru Yes Yes Yes
1
36C03A-410
Standing
Pilot
120VAC Natural
or
LP
3
/
4
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
Yes Str. Thru Yes
No No 3
36C03U-333
Standing
Pilot
750mV Natural
or
LP
1
/
2
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
Yes Str. Thru Yes Yes Yes
2
36C03U-433
Standing
Pilot
750mV Natural
or
LP
3
/
4
x
3
/
4
Fast Open 3.5
”
2.5
”
-5.0
”
Yes
Yes
Yes Str. Thru Yes Yes Yes
2
36C04U-438
Standing
Pilot
750mV Natural
or
LP
3
/
4
x
3
/
4
Step Open
0.7"
0.7 / 3.5
”
2.5
”
-5.0
”
No
No
Yes Str. Thru Yes
No No 2
36C53-418
Standing
Pilot
24VAC Natural
or
LP
3
/
4
x
3
/
4
Slow Open 3.5
”
2.5
”
-5.0
”
Yes
No
Yes Str. Thru Yes
No No 1
36C03-258
Standing
Pilot
24VAC Natural
or
LP
1
/
2
x
1
/
2
Fast Open 3.5
”
2.5
”
-5.0
”
No
No
Yes Str. Thru No Yes No 1
U
U
www.white-rodgers.com38
HEATING