ELECTRIC WATER

HEATER THERMOSTATS

APPLIANCE

CONTROLS

ELECTRIC WATER HEATER THERMOSTATS

AND LIMITS – UNIVERSAL REPLACEMENTS

Surface Mount Temperature Sensing Controls

FEATURES

• High electrical capacity.

• Snap-Action contact.

• Long life-proven reliability.

• Adjustable control or manual reset styles.

SPECIFICATIONS

Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. and C.S.A. approved

754-1

A.C. Electrical Ratings

Model

Switch

(Non-Inductive)

Number

Description

Action

Range

120 / 240 VAC

277 VAC

480 VAC

754-1

DPST limit (manual reset)

Open on Rise

170°F fixed (77°C)

40.0A

25.0A

755-1

SPST thermostat

Open on Rise

90 to 150°F(32 to 66°C)

30.0A

25.0A

12.5A

755-50

754-1 + 755-1

30.0A

25.0A

12.5A

756-1

SPDT thermostat

Open 1-2 on Rise

90 to 150°F(32 to 66°C)

30.0A

25.0A

12.5A

756-50

754-1 + 756-1

30.0A

25.0A

12.5A

755-1

755-50

756-1

756-50

www.white-rodgers.com