APPLIANCE VALVES
2500 SERIES REPLACEMENT GAS VALVE COILS
FEATURES
• Easy installation of replacement coil assemblies.
• Available for most popular models.
• Single or complete coil sets
F91-3890
F91-3889
25M
SERIES DRYER VALVES
Model
Coil
Outlet Flow
Inlet/Outlet
Regulator
Number
Voltage
Direction
Size
Adjustment Range
25M01A-100
120 VAC Right Angle Left
3
/
8
”
NPT X
11
/
32
”
Nat. Gas: 2.8
”
to 5.4
”
W.C.
25M01A-101
120 VAC Right Angle Right
3
/
8
”
NPT X
1
/
32
”
LP Gas: 8.5
”
to 12.0
”
W.C.
(Conversion Kit Included)
Mounting Position – Control may be mounted in the following positions: horizontal, vertical or 90° of horizontal.
Do not mount upside down
.
25M01A-101
Model
Number
Application
Description
OEM
F91-3889
25M01A-xxx
120V Coil Replacement for 25M
valve individual pack secondary coil
Used on Whirlpool, Electrolux, GE,
Maytag, Speed Queen
F91-3890
25M01A-xxx
120V Coil Replacement for 25M
valve individual pack booster and
holding coil
Used on Whirlpool, Electrolux, GE,
Maytag, Speed Queen
F91-4241
25M01A-xxx
Boost/host coil and secondary coil
(120V, 60 Hz) for 25M dryer gas
valve (includes F91-3889 plus
F91-3890 combined)
Used on Whirlpool, Electrolux, GE,
Maytag, Speed Queen
25M01A-100 and 25M01A-101
25M01A Series Gas Valves Combine a Gas Pressure Regulator with
Redundant and Main Solenoid Valves for Hot Surface Ignition (HSI)
Residential Gas Clothes Dryers. Two Models to Replace Virtually All
Whirlpool, Maytag, GE, Frigidaire, Electrolux, or Speed Queen Gas
Dryer Valves
FEATURES
• Compact split coil design.
• Inlet/outlet screen.
• Field-adjustable regulator.
• Replaceable operating coils (no gas interruption).
• Outlet pressure tap.
• Both models packaged with the most popular main burner orifices to replace
many OEM models.
SPECIFICATIONS
Type of Gas . . . . . . . . . . . Natural or LP gas (conversion kit included)
Pressure Regulator Setting . . . . . Nat. Gas: 2.8
”
to 5.4
”
W.C.
. . . . . . . . . . . . . . . LP Gas: 8.5
”
to 12.0
”
W.C.
Operating Ambient . . . . . . . . Temperature: 32° to 155°F
Max. Pressure Rating . . . . . . . 14
”
W.C. (½ PSI) max.
Electrical . . . . . . . . . . . . 120 VAC, 60 Hz, .06 amps
1
”
P.D. Capacity . . . . . . . . . 40,000 BTU/HR
PARTS AND ACCESSORIES
• F91-3889 — Replacement Coil (Secondary)
• F91-3890 — Replacement Coil (Boost/Hold)
www.white-rodgers.com110
HYDRONIC /