101
TYPE 70 CONTACTORS – SPNO
Single Pole Normally Open Contact, Case is Dust Resistant and
Isolated from Ground
SPECIFICATIONS
Dimensions . . . . . . . . . . . . .
2.47
”
L x 3.48
”
W x 2.40
”
H
Weight . . . . . . . . . . . . . . . . . 14 oz.
Temperature Range . . . . . . . . . .
-40° to +122°F
Terminations, Contacts . . . . . . . .
5
/
16
”
-24 UNF-2A thread
Terminations, Coil . . . . . . . . . .
#10-32 UNF-2A thread
Recommended Mounting . . . . . . . . . Plunger vertical with cap down
Hardware Torque, Contact Terminal . . . . . 45-55 in. lbs.
Hardware Torque, Coil Terminal . . . . . . . 12-18 in. lbs.
Caution
: A back-up wrench must be used to hold the bottom nut stationary.
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. 538 Recognized, File AU2138
➀
“3A” = Coil Grounded to Case
“4” = Isolated Coil
➁
Coil resistance in Ohms @ 25°C
➂
Intermittent duty designs available.
TYPE 120 CONTACTORS – SPNO
Single Pole Normally Open Contact, Dust Resistant, Water Resistant
and Case is Isolated from Bracket
SPECIFICATIONS
Dimensions . . . . . . . . . . . . .
2.13
”
L x 2.88
”
W x 3.09
”
H (Std. Bracket)
Dimensions . . . . . . . . . . . . .
2.50
”
L x 3.00
”
W x 3.03
”
H
(L-Shaped Bracket)
Weight . . . . . . . . . . . . . . . . . 6.0 oz.
Temperature Range, Intermittent Duty . .
-20° to +150°F
Temperature Range, Continuous Duty . .
-20° to +120°F
Terminations, Contacts . . . . . . . .
5
/
16
”
-24 studs, .495
”
min. length
Terminations, Coil . . . . . . . . . .
#10-32, .451
”
min. length
Recommended Mounting . . . . . . . . . Coil terminals up or horizontal
Hardware Torque, Contact Terminal . . . . . 45-55 in. lbs.
Hardware Torque, Coil Terminal . . . . . . . 12-18 in. lbs.
Caution
: A back-up wrench must be used to hold the bottom nut stationary.
Type 120 SPNO
DC POWER
CONTACTORS – SPNO
➀
Intermittent Duty Cycle = 30 seconds “ON” maximum and 6 minutes “OFF”
➁
“4” = Isolated Coil
➂
Coil resistance in Ohms @ 25°C
➃
Inrush Current: Current applied within the first 1/2 second of contact closure
➄
Coil grounded to bracket
NOTE
: CAUTION must be used in coil selection for use in 12 volt
systems where battery charging may expose coil to continuous,
higher-than-rated voltage. 14 volt coils are recommended.
White-Rodgers will not be responsible for consequences of
misapplied solenoids.
WARNING – FIRE HAZARD
Must be installed in a dry and protected
place. Failure to protect solenoid from water
and other contaminants could result in Fire,
Property Damage, Serious Personal Injury,
or Death.
Type 70 SPNO
Model
Number
Duty
Cycle
➂
Terminal
Type
➀
Pole
Form
Bracket
Style
Coil
Voltage
D.C.
Coil
Resistance
(Ohms)
➁
Contact
Material
Contact Rating (Amps) – Inductive Load
Voltage
Normally Open
D.C.
Continuous Inrush
70-111225
Continuous
3A SPNO Standard 12
16
Copper
12
80
150
70-111224
Continuous
4
SPNO Standard 12
16
Copper
12
80
150
70-117224
Continuous
4
SPNO Standard 24
60
Copper
24
50
50
70-120224
Continuous
4
SPNO Standard 36
114
Copper
36
50
50
Model
Number
Duty
Cycle
➀
Terminal
Type
➁
Pole
Form
Bracket
Style
Coil
Voltage
D.C.
Coil
Resistance
(Ohms)
➂
Contact
Material
Contact Rating (Amps) – Inductive Load
Voltage
Normally Open
D.C.
Continuous
Inrush
➃
120-105711
Continuous
4
SPNO Standard 12
16
Silver Alloy
12
100
400
120-105851
Continuous
3A SPNO Standard 12
➄
16
Silver Alloy
12
100
400
120-106131
Intermittent
4
SPNO Standard 12
6.0
Copper
12
80
400
120-106132
Intermittent
4
SPNO L
12
6.0
Copper
12
80
400
120-107112
Continuous
4
SPNO L
14
26.0
Silver Alloy
14
100
400
TRANSFORMERS /