THERMOSTATS

?

pages

127

TECHNICAL HELP

Connections....................................................................................See page 127

www.white-rodgers.com

9

EASY INSTALL

THERMOSTAT

1HDEZ-1521

Includes User Interface and

Equipment Control

Inspire

Universal 4-Wire Color

Thermostat System

Upgrade Single Stage Applications to Premium High-Efficiency

Systems (Staging, Heat Pump or Heat Pump with Dual Fuel) – Using

Existing 4 Wires

FEATURES

• Reusable plug-in configuration tool – eliminates multiple trips up and down stairs

during set up and system testing.

• USB port to quickly upload your favorite Installation Settings, Programs and

personalized Company Contact Information.

5

/

8

thin profile with vibrant color display.

• Color coded LEDs provide positive feedback for easy setup.

• Dehumidification, humidification.

DIMENSION

Interface ..................... 3

1

/

4

H x 6

1

/

8

W x

5

/

8

D

Control ........................ 5

1

/

2

H x 5

3

/

4

W x 1

1

/

2

D

SPECIFICATIONS

Electrical Rating:

Hardwire . . . . . . . . . . . . 20-30 VAC, NEC Class II 50/60Hz or DC

Terminal Load . . . . . . . . . . 1.5 A per terminal,

2.5 A maximum load (all terminals combined)

Setpoint Range . . . . . . . . . 45 to 99°F (7 to 37°C)

Rated Differential . . . . . . . . . Heat 0.6°F; Cool 1.2°F

Operating Ambient . . . . . . . . 32 to +105°F (0 to +41°C) – Interface

-30 to +150°F (-34 to 66°C) – Control

Operating Humidity Range . . . . . 90% non-condensing maximum

PARTS AND ACCESSORIES

See end of thermostats section for additional parts and accessories

• F4-1400 — Thermostat Plug-in Configuration Tool

• F145-1378 — Outdoor Remote Sensor

• F29-0198 — Locking Thermostat Guard - Clear Plastic

• F29-0220 — Locking Thermostat Guard - Metal, Solid Base

• F29-0222 — Locking Thermostat Guard - Metal, Ring Base

Inspire

Universal 4-Wire Color Thermostat System

24 VOLT

Single

Stage

Multi-

Stage

Heat

Pump

Programs

Model

Applications

Thermostat Power Source*

Selectable Performance Features

Display Size (Square inches)

Terminals

Stages Heat/Cool

by System

Program

Options

Periods

per day

Options

Model

Number

Gas / Oil / Electric

3 Wire Zone Valve

Millivolt Compatible

Humidity Control

(H)-Humidity / (D)-Dihumidity

Auto Changeover

Programmable Fan

Energy Aware

Comfort Alert®

A.C. System Protection

(P)-Passive/(A)-Active§

Dual Fuel Heat Pump Control

(L)-Logic/(O)-Outdoor Sensor

Dual Fuel Heat Stages HP/Gas

Aux. Heat Lockout with

Outdoor Sensor

Keypad Lockout

(T)-Total/(P)-Partial

Setpoint Temperature Limits

Adjustable Max./Min.

Indoor Remote Sensors

Max. Number + Thermostat

Average and/or Weighted

Remote Temperature Sensing

RC, RH, C, W/E, W2, Y,

Y2, O/B, G, L, +, S, -,

DHM, DHM2, HM, HM2,

R, 1, 2, C- Thermostat 1,

2, C, R

1/1 2/2 4/2 7, Ø 4, Ø

1HDEZ-1521

H,D H

 

A 0 ‡ 2/2

 

1 5.5

*H = Hardwired (Requires Common)

When used with an outdoor sensor provides options

to lock out auxiliary heat above selected outdoor

temperature.