THERMOSTATS

SINGLE STAGE THERMOSTAT – BLUE 12

THERMOSTATS

Single

Stage

Multi-

Stage

Heat

Pump

Programs

Model

Applications

Thermostat Power Source*

Selectable Performance Features

Comfort and

Convenience

Features

Terminals

Stages Heat/Cool

by System

Program

Options

Periods

Per Day

Options

Model

Number

Gas / Oil / Electric

3 Wire Zone Valve

Millivolt Compatible

Economizer

Humidity Control

(H)-Humidity / (D)-Dehumidify

Auto Changeover

Programmable Fan

Energy Mgt. Recovery

Dual Fuel Heat Pump Control

(L)-Logic / (O)-Outdoor Sensor

Keypad Lockout

(T)-Total / (P)-Partial

Set-Point Temperature Limits

Adjustable Max/Min

Indoor Remote Sensors

Max. Number + Thermostat

Average and/or Weighted

Outdoor Remote Sensor

Display Size

(Square inches)

Lighted Display

Cool Savings

Memory Back-Up

(P)-Permanent / (B)-Battery

1/1

2/1 7, 5+1+1,

Ø

4, 2, Ø

1F97-1277

3 3 3

B, H

3 3 3

L, O

T, P

3

1+1 1

t

12.0

3

***

3

P RC, RH, C, W/E, Y,

O/B, G, L, 6, +, S, -

UNIVERSAL STAGING/HEAT PUMP THERMOSTATS – BLUE 12

THERMOSTATS

Single

Stage

Multi-

Stage

Heat

Pump

Programs

Model

Applications

Thermostat Power Source*

Selectable Performance Features

Comfort and

Convenience

Features

Terminals

Stages Heat/Cool

by System

Program

Options

Periods

Per Day

Options

Model

Number

Gas / Oil / Electric

3 Wire Zone Valve

Millivolt Compatible

Economizer

Humidity Control

(H)-Humidity / (D)-Dehumidify

Auto Changeover

Programmable Fan

Energy Mgt. Recovery

Dual Fuel Heat Pump Control

(L)-Logic / (O)-Outdoor Sensor

Keypad Lockout

(T)-Total / (P)-Partial

Set-Point Temperature Limits

Adjustable Max/Min

Indoor Remote Sensors

Max. Number + Thermostat

Average and/or Weighted

Outdoor Remote Sensor

Display Size

(Square inches)

Lighted Display

Cool Savings

Memory Back-Up

(P)-Permanent / (B)-Battery

1/1 2/2 4/2 7, 5+1+1,

Ø

4, 2, Ø

1F95-1291

Humidity

Control

3 3 3

H, D B, H,

PA

3 3 3

L, O

T, P

3

1+1 1

t

12.0

3

***

3

P RC, RH, C, W/E, W2,

Y, Y2, O/B, G, L, 6, +,

S, -, DHM, HM

1/1 2/2 4/2 7, 5+1+1,

Ø

2, Ø

1F95-1280

Commercial

3 3 3 3

B, H,

PA

3 3 3

L, O

T, P

3

1+1 1

t

12.0

3

***

3

P RC, RH, C, W/E, W2,

Y, Y2, O/B, G, L, 6, +,

S, -, A1

1/1 2/2 3/2◙ 7, 5+1+1,

Ø

4, 2, Ø

1F95-1277

Universal

3 3 3

B, H

3 3 3

L, O

T, P

3

1+1 1

t

12.0

3

***

3

P RC, RH, C, W/E, W2,

Y, Y2, O/B, G, L, 6,

+, S, -

* H = Hardwired (Requires Common)

If F145-1378 outdoor remote sensor is not used, install manufacturers

B, H = Battery Powered or Hardwired

fossil fuel kit for Dual Fuel applications

B = Battery Powered

*** Optional Continuous Display Light w/ Hardwire connection

PA = Power Saving Battery Assist

t

Only one (1) remote sensor may be used – either Indoor or Outdoor

◙ 4/2 on Dual Fuel using Outdoor Remote Sensor

?

BLUE 12

TOUCHSCREEN

THERMOSTATS

pages

131–138

TECHNICAL HELP

1F97-1277..........................Wiring Diagrams/Configuration...........See pages 131–132

1F95-1280 / 1F95-1291....Wiring Diagrams/Configuration...........See pages 133–136

1F95-1277..........................Wiring Diagrams/Configuration...........See pages 137–138

www.white-rodgers.com

13