760-56
760-56 IGNITION ELECTRODE ASSEMBLIES
Use Type 760-56 to Replace Cycle-Pilot
®
Ignition Electrodes and
Cable Assemblies
5059-23
Pilot Relite Control
PILOT RELITE / IGNITION
ELECTRODE / FLAME SENSORS
SPARK / HSI IGNITION
5059 SERIES pilot relite controlS
Generates Spark Until a Pilot Flame is Sensed
FEATURES
• Generates spark pulse until flame is sensed through spark electrode.
• Begins sparking immediately if flame extinguishes.
• Rugged solid state module design.
• Spark plug or spike output configurations available.
SPECIFICATIONS
Agency . . . . . . . . . . . . . . . . . . . . . . C.S.A. approved
Number
Model
Input
Voltage
Electrical
Rating
Description
5059-23
24 VAC
0.03 amps Spark plug and
1
/
4
”
spade connectors
5059-134
24 VAC
0.03 amps Spike connector
Number
Model
Description
760-56
24
”
lead with slip on bracket. Also includes perforated mounting strap for varying
applications
Model
Number Lead Length Electrical Connection
760-401
30
”
1
/
4
”
female spade terminal
760-802
➀
30
”
1
/
4
”
female spade terminal
➀
Exact replacement for O.E.M. model
760 SERIES FLAME SENSORS FOR HSI
Flame Sensors can be Mounted Remotely on Multiple Burners
FEATURES
• High quality Alumina ceramic insulator.
• High temperature Kanthal flame rod material that can withstand 1800°F.
• Teflon insulated (250°C rating) lead wire.
• Single screw, plated steel mounting bracket.
SPECIFICATIONS
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . C.S.A approved
760-401
Flame Sensor
www.white-rodgers.com58
HEATING