THERMOSTATS
UNIVERSAL STAGING/HEAT PUMP THERMOSTATS – CLASSIC 80 SERIES THERMOSTATS
Single
Stage
Multi-
Stage
Heat
Pump
Programs
Model
Applications
Thermostat Power Source*
Selectable Performance
Features
Comfort and
Convenience
Features
Terminals
Stages Heat/Cool
by System
Program
Options
Periods
Per Day
Options
Model
Number
Gas / Oil / Electric
3 Wire Zone Valve
Millivolt Compatible
Humidity Control
(H)-Humidity / (D)-Dehumidify
Auto Changeover
Programmable Fan
Energy Mgt. Recovery
Keypad Lockout
(T)-Total / (P)-Partial
Set-Point Temperature Limits
Adjustable Max/Min
Indoor Remote Sensors
Max. Number + Thermostat
Average and/or Weighted
Outdoor Remote Sensor
Display Size
(Square inches)
Lighted Display
Cool Savings
Memory Back-Up
(P)-Permanent / (B)-Battery
1/1 2/2 3/2 7, 5+1+1
Ø
4, 2, Ø
1F85-277
Universal
3 3
B, H
3 3
T
3
2.2
3
***
P R, C, E/W1, W2, Y1,
Y2, O/B, G, L
2/1 5+1+1 4
1F82-261
Heat Pump
H
3
1.8
3
***
P R, C, W2, E, Y, O/B,
G, L
2/1
Ø
Ø
1F89-0211
Heat Pump
H
1.8
3
***
P R, C, W2, E, Y, O/B,
G, L
SINGLE STAGE THERMOSTATS – CLASSIC 80 SERIES THERMOSTATS
Single
Stage
Multi-
Stage
Heat
Pump
Programs
Model
Applications
Thermostat Power Source*
Selectable Performance
Features
Comfort and
Convenience
Features
Terminals
Stages Heat/Cool
by System
Program
Options
Periods
Per Day
Options
Model
Number
Gas / Oil / Electric
3 Wire Zone Valve
Millivolt Compatible
Humidity Control
(H)-Humidity / (D)-Dehumidify
Auto Changeover
Programmable Fan
Energy Mgt. Recovery
Keypad Lockout
(T)-Total / (P)-Partial
Set-Point Temperature Limits
Adjustable Max/Min
Indoor Remote Sensors
Max. Number + Thermostat
Average and/or Weighted
Outdoor Remote Sensor
Display Size
(Square inches)
Lighted Display
Cool Savings
Memory Back-Up
(P)-Permanent / (B)-Battery
1/1
1/1 7-day
4
1F87-361
3 3
B, H
3
2.2
3
P RC,RH, C, W, Y,O,
B, G
1/1
1/1 5+1+1 4
1F80-361
3 3
B, H
3
2.2
3
P RC,RH, C, W, Y,O,
B, G
1/1
1/1
Ø
Ø
1F86-344
3 3
B, H
2.2
3
P RC,RH, C, W, Y,O,
B, G
CLASSIC 80 SERIES
THERMOSTATS
?
24 VOLT
* H = Hardwired (Requires Common)
Heat Pump for Stage 1, and Gas / Oil / Electric for 2nd stage / Emergency
B, H = Battery Powered or Hardwired
*** Optional Continuous Display Light w/ Hardwire connection
B = Battery Powered
pages
159–161
TECHNICAL HELP
1F80-224 -240, -241, -361 /
1F86-241, -344 / 1F87-361...Wiring Diagrams/Configuration.........See page 159
1F82-261 / 1F89-211. ............Wiring Diagrams/Configuration.........See page 160
1F85-277...............................Wiring Diagrams/Configuration.........See page 161
www.white-rodgers.com21