217
SQS1072R
SQS1152R
Two Compartment Square Flange Pool Motors • Two Speed
Q3052
Important:
1. Total output (HP x service factor) of replacement motor
must equal or exceed motor being replaced.
2. The pool motors on this page are
NOT equipped with a
Safety Vacuum Release System (SVRS)
. SVRS helps
prevent drowning due to body entrapment on underwater
drains. In some pool configurations, if a person’s body
covers the drain, the person can be trapped by suction.
The SVRS turns off the pump if this occurs.
Depending on your pool configuration,
a SVRS may be required to meet local, state, and federal
requirements.
Used on many Sta-Rite, Red Jacket, and Sears Jet and Pool Pumps.
Features:
• All Copper Windings • Auto Protector - Single Phase
• Open Dripproof • Rotation: CCW Pump End • Class B Insulation
• 303 Stainless Steel Threaded Shaft • 50°C Ambient • 60 Hz
• Energy Efficient Capacitor Start Low Speed, PSC High Speed • UL1081
Two-speed motors are shipped less hi/lo switch for remote operation.
End cover and switch assembly kit number 615332 available and sold separately.
HIGH SERVICE FACTOR (FULL RATED)
Amps
Stock
Approx.
HP
RPM Volts
Hi - Lo S.F.
Frame
Number
“AG”
Notes
3/4~1/8
3450/1725 115
13.0/4.2 1.65
48Y
SQL1072R
H
12-5/8
$
230
6.1/2.1 1.60
48Y
SQS1072R
H
12-5/8
$
1~1/6
3450/1725 230
7.7/2.8 1.65
48Y
SQS1102R
H
13-13/16
$
1-1/2~1/4
3450/1725 230
10.0/3.0 1.47
48Y
SQS1152R
H
13-9/16
$
2~1/3
3450/1725 230
11.3/3.3 1.3
48Y
SQS1202R
H
13-13/16
$
LOW SERVICE FACTOR (UP-RATED)
Amps
Stock
Approx.
HP
RPM Volts
Hi - Lo S.F.
Frame Number
“AG”
Notes
1~1/6
3450/1725 230
6.1/2.1 1.25
48Y
UQS1102R
H
12-5/8
$
1-1/2~1/4
3450/1725 230
9.5/2.5
1.1
48Y
UQS1152R
H
13-13/16
$
2~1/3
3450/1725 230
10.0/3.0 1.1
48Y
UQS1202R
H
13-9/16
$
Three Phase Square Flange Pump Motors
Features:
All Copper Windings • Open Dripproof • 303 Stainless Steel Threaded Shaft • Sealed Ball Bearings • 50°C Ambient • 60 Hz
Featur
d Ball
Bearings
Max.
Service
Stock Overload Approx.
HP
RPM
Volts
Amps
Factor Frame Number Protector
“AG”
Notes
1/2
3450
208-230/460 3.0/1.5
1.9
48Y
Q3052
None
9-7/8
3/4
3450
208-230/460 3.6/1.8
1.65
48Y
Q3072
None
10-3/8
1
3450
208-230/460 4.7/2.35
1.65
48Y
Q3102
None
10-7/8
1-1/2
3450
208-230/460 6.8/3.4
1.47
48Y
Q3152
None
11-7/8
2
3450
208-230/460 8.5/4.25
1.3
48Y
Q3202
None
12-5/8
3
3450
200-230/460 9.7/4.9
1.15
56Y
Q3302V1
None
12
31
Notes:
31. 40 degree C ambient
See page 268 for mounting dimensions.