210
Two Compartment NEMA C-Face Pool Filter Motors • Single Speed
Features:
• Auto Protector • Capacitor Start and Capacitor Start-Capacitor Run
• NEMA “56C” Face Mount
• Open Dripproof • Rotation: CCW Pump End • Sealed Ball Bearings
• Sealed Switch Design • “1081” Design • 50°C Ambient • 60 Hz
• 303 Stainless Shaft (56J & 56C) • 304 Brg. Shaft End
LOW SERVICE FACTOR (UP-RATED) - STANDARD EFFICIENCY AND “CONSERVATIONIST
TM
HIGH EFFICIENCY DESIGNS
Max.
Service
Stock
Approx.
HP
RPM Volts
Amps
Factor
Frame Number
Shaft
“AG”
Notes
3/4
3450
115/230
11.0/5.5
1.0
56J
UST1072
Thd.
10-5/8
115/230
8.0/4.0
1.0
56J
UCT1072
H
Thd.
11
20,
$
1
3450
115/230
15.0/7.5
1.1
56J
UST1102
Thd.
11
115/230
11.0/5.5
1.0
56J
UCT1102
Thd.
11-11/16
20,
$
1-1/2
3450
115/230
18.6/9.3
1.0
56J
UST1152
Thd.
12-1/8
115/230
14.6/7.3
1.0
56J
UCT1152
Thd.
12-1/8
20,
$
2
3450 115/208-230 19.6/10.4-9.8
1.1
56J
UST1202
Thd.
12-5/8
20,
$
2-1/2
3450
208-230
12.6/11.4
1.1
56J
UST1252
Thd.
13-1/16
20,
$
Notes:
 20.
$
Energy Efficient capacitor start, capacitor run “Conservationist
TM
” motor
H
Meets California Energy Commission Appliance Regulations 2008
(Publication Number CEC-400-2006-002-REV1)
UST1072
Important:
1. Total output (HP x service factor) of replacement motor
must equal or exceed motor being replaced.
2. The pool motors on this page are
NOT equipped with a
Safety Vacuum Release System (SVRS)
. SVRS helps
prevent drowning due to body entrapment on underwater
drains. In some pool configurations, if a person’s body
covers the drain, the person can be trapped by suction.
The SVRS turns off the pump if this occurs.
Depending on your pool configuration,
a SVRS may be required to meet local, state, and federal
requirements.
1...,202,203,204,205,206,207,208,209,210,211 213,214,215,216,217,218,219,220,221,222,...324