213
Century® C-Face Pool and Spa Pump Motors
Features:
• Ball Bearings • 50°C Ambient • 60 Hz • Class B Insulation
• Rotation: CCW Pump End • 304 Bearing Shaft End
Centurion
®
“1081” • Full Rate • High Service Factor • Aluminum NEMA “C” Brackets
Service
Factor
Service
Stock
Overload
“C”
HP RPM
Volts
Amps
Factor
Frame
Number
Protector
Shaft
Dimension
Notes
1/2
3450
230/115
4.4/8.8
1.60
56C
B120
H
Auto
Keyed
11.44
230/115
4.4/8.8
1.60
56J
B126
H
Auto
Threaded
11.94
12
3/4
3450
230/115
6.0/12.0
1.50
56C
B121
Auto
Keyed
11.44
230/115
6.0/12.0
1.50
56J
B127
Auto
Threaded
12.01
12
1
3450
230/115
7.2/14.4
1.40
56C
B122
Auto
Keyed
11.89
230/115
7.2/14.4
1.40
56J
B128
Auto
Threaded
12.14
12
1-1/2
3450
230/115
9.2/18.4
1.30
56C
B123
Auto
Keyed
13.19
230/115
9.2/18.4
1.30
56J
B129
Auto
Threaded
13.50
12
2
3450
230/115
10.8/21.6
1.20
56C
B835
Auto
Keyed
13.94
230
10.5
1.20
56C
B124
Auto
Keyed
12.55
230/115
10.8/21.6
1.20
56J
B836
Auto
Threaded
13.90
12
230
10.5
1.20
56J
B130
Auto
Threaded
13.10
12
3
3450
230
14.1
1.15
56C
B125
Auto
Keyed
13.65
230
14.1
1.15
56J
B131
Auto
Threaded
14.15
12
4
3450
208-230
21.0-19.4
1.25
56Y
B116
Manual
Special
16.78
31,34,63,236
Centurion
®
SE “1081” • Up Rate • Low Service Factor
Service
Factor
Service
Stock
Overload
“C”
HP RPM
Volts
Amps
Factor
Frame
Number
Protector
Shaft
Dimension
Notes
3/4
3450
230/115
4.4/8.8
1.00
56J
B227SE
H
Auto
Threaded
12.56
12
1
3450
230/115
6.0/12.0
1.00
56J
B228SE
Auto
Threaded
12.81
12
1-1/2
3450
230/115
7.2/14.4
1.00
56J
B229SE
Auto
Threaded
13.91
12
2
3450
230/115
9.2/18.4
1.00
56J
B230SE
Auto
Threaded
14.31
12
2-1/2
3450
230
10.5
1.00
56J
B231SE
Auto
Threaded
13.81
12
Notes:
12.
303 Stainless steel shaft
31. 40 degree C ambient
34. Rigid base
63. Speck Pump replacement motor
236. CCW Rotation facing opposite shaft end
H
Meets California Energy Commission Appliance Regulations 2008
(Publication Number CEC-400-2006-002-REV1)
B126
Permanent Split Capacitor – Switchless – Single Phase – Dripproof
No Base – 3450 RPM 1/2 thru 4 HP
Important:
1. Total output (HP x service factor) of replacement motor
must equal or exceed motor being replaced.
2. The pool motors on this page are
NOT equipped with a
Safety Vacuum Release System (SVRS)
. SVRS helps
prevent drowning due to body entrapment on underwater
drains. In some pool configurations, if a person’s body
covers the drain, the person can be trapped by suction.
The SVRS turns off the pump if this occurs.
Depending on your pool configuration,
a SVRS may be required to meet local, state, and federal
requirements.