223
Sta-Rite Direct Replacement Spa Motors
Features:
• Open Construction
• Rigid Base
• Sealed Ball Bearings
• Threaded Shaft
• Through Bolt Mount
• 50˚C Ambient
• 1.0 Service Factor
•
$
Energy Efficient
• Auto Protector
• Rotation: CCW Pump End
• 2-Speed (Capacitor Start Low Speed, PSC High Speed)
Four Thru Bolts on a 5.146 Bolt CircleReplacement Motor for Dimension One, Hydroquip, GPM Industries, Hawkeye, Marquis and Master Spas
Stock
Insulation Approx.
Dim.
HP
RPM Volts Amps Frame
Number
Class
“AG”
“BX”
Notes
1.0-.12 3450/1725 115 10.4/3.6
56Z
SDS1102
H
B
10.30
8.85
$
1.5-.19 3450/1725 230
7.2/2.4
56Z
SDS1152
H
F
10.79
9.34
$
2.0-.25 3450/1725 230
8.5/3.0
56Z
SDS1202
H
F
11.42
9.98
$
2.5-.25 3450/1725 230 10.7/3.0
56Z
SDS1252
H
F
10.67
9.23
$
3.0-.38 3450/1725 230 12.0/3.7
56Z
SDS1302
H
F
10.92
9.48
$
Note:
When crossing to an original equipment A. O. Smith Motor, use the Quick Cross Reference table. Find the amps and model number of the OEM motor on
the motor nameplate. Find the equivalent amps and model number on the Quick Cross Reference table below. The replacement is the stock number listed
in the “Use” column. The horsepower and service factor may not be the same, but the motors are the same.
Quick Cross Reference By Amps and Motor Model Number
Name Plate
Name Plate
Use
Amps
Model No.
Stock No.
10.4/3.6
K48L2A1
SDS1102
7.2/2.4
K48M2A4
SDS1152
8.5/3.0
K48N2A5
SDS1202
10.7/3.0
K48N2A4C2
SDS1252
12.0/3.7
K48P2A1
SDS1302
H
Meets California Energy Commission Appliance Regulations 2008
(Publication Number CEC-400-2006-002-REV1)
SDS1102
Above Ground Swimming Pool Pump Motors
Jetted Tub/Spa/Above Ground Swimming Pool Pump Motors – Split Phase, Capacitor
Start & PSC Single-phase – Dripproof – Ball Bearing – Rigid Base & No Base – 3450 and
3450/1725 RPM – 1/2 thru 4 HP SP
BV90
Hoffinger Replacement (Doughboy/Lomart) • No Base
Full Load
Service
Stock
Overload “C”
HP
RPM
Volts
Hz
Amps
Factor
Frame
Number
Shaft
Protector
Dim.
Notes
1
3450
115
60
10.0
1.0
48Y
BV90
Threaded
Auto
10.45
115
60
9.0
1.0
48Y
BV91
Threaded
Auto
10.22
285
Notes:
285. 3/8-16, Left hand threads, CWPE rotation
H
Meets California Energy Commission Appliance Regulations 2008 (Publication Number CEC-400-2006-002-REV1)
Continued from previous page
Important:
The pool motors on this page are
NOT equipped with a
Safety Vacuum Release System (SVRS)
. SVRS helps
prevent drowning due to body entrapment on underwater
drains. In some pool configurations, if a person’s body
covers the drain, the person can be trapped by suction.
The SVRS turns off the pump if this occurs.
Depending on your pool configuration,
a SVRS may be required to meet local, state, and federal
requirements.