200
Features:
• Auto Protector
• Class B Insulation
• Direct Drive
• Double Sealed Ball B earings
• Extended 10-32 Thru-bolts 3/4” Past Nut
• Fully Gasketed
Full Load
Stock
“C”
HP
RPM Speeds
Volts
Amps
Frame
Number
Shaft
Dim.
Notes
resilient base
1/4
1700
1
115/230
3.4/1.7
48Z
C042A
1/2 x 3-1/8
10.1
70,132,133
1/4
1100
1
115/230
4.0/2.0
48Z
C045A
1/2 x 3-1/4
9.3
70,132,133
1/4
1100
2
115
3.4
48Z
C059A
1/2 x 3
10.1
70
1/3
1725
1
115/230
3.6/1.8
48Z
C043A
1/2 x 3-1/8
10.1
70,132,133
1/3
1100
1
115/230
4.2/2.3
48Z
C046A
1/2 x 3-1/4
10.0
70,132,133
1/2
1700
1
115/230
5.5/2.8
48Z
C044A
1/2 x 3
11.0
70,132,133
1/2
1100
1
115/230
6.5/3.25
48Z
C047A
1/2 x 3-1/8
11.1
70,132,133
1/2
900
1
115/230
7.1/3.6
48Z
C039A
1/2 x 2-1/2
11.0
70,132,133
1/2
900
1
115/230
6.6/3.3
56Z
C048
5/8 x 2-1/2
12.1
70,134
Thru Bolt Mount (10-32 UNF-2A)
1/3
1800
1
115
4.8
56Z
F683
1⁄2 x 2
11.12
62
1/3
1800/900
2
115
5.5/3.1
56Y
F684
1⁄2 x 2
11.12
62
1/3
1200
1
115
4.7
48Z
971
1/2 x 2
6.80
1,3,70,146,228
Rigid Base
1
900
1
230
5.1
56CZ
C783
5⁄8 x 3-1⁄4
14.22
6,44,70
Notes
:
1. Item to be discontinued when stock is depleted
3. Special OEM replacement motor
6. 60/50 Hertz
44. CCWLE rotation only
62. Split Phase
70. Permanent Split Capacitor
132. Shaft sleeve and key supplied for
5
/
8
” diameter
133. Shaft N-W = 2.50” with two flats .04 deep, 2.16” long, 90° apart
134. Shaft N-W = 2.50” with
5
⁄
8
” diameter and keyway
146. No base
228. CWSE not reversible
971
(Hired Hand)
C048
C783
F683, F684
C039A
C042A
C043A
C044A
C045A
• Reversible
• Service Factor 1.0
• Single Phase
• 60 Hz
• 40°C Ambient
• Totally Enclosed, Air Over
Century® Farm Building Direct Drive Fan Motors
Applications:
Designed for farm air movement applications.
C046A
C047A
C059
C059A