POWER
PILOT
CONTACT
208/240V
208/240V
RATINGS
120V 277V 120V 277V
Full Load Amps
12
6
-
-
Resistive Amps*
15
15
3
3
Locked Rotor Amps 60 35
-
-
Horsepower
3/4 3/4 1/10 1/10
63
*0.75 power factor
Relays
Replacing all potential relays, these WIRE TO WIRE Universal Potential Relays offer the ultimate in convenience. One potential relay to fit any application.
Choose to “drop in” the SUPR Universal Potential Relay or “dial in” the exact pick-up voltage for the APR5 Adjustable Potential Relay. State of the Art
electronic circuitry provides Wire to Wire replacement of any potential relay with added motor protection.
Features/Benefits
• Reduces inventory
• Wire to Wire Replacement for virtually
ALL potential relays.
• Recycles instantly
Universal Potential Relays
SUPR Universal Potential Relay
• Time Function Relay
• Start Time: 1.0 - 0.5 seconds
APR5 Adjustable Potential Relay
• Adjustable, Voltage Sensitive Relay
• Set pick-up voltage
• Safety time out 1.0 – 1.5 seconds
Common Specifications
Operating Voltage
110 – 270 VAC, Single Phase
Amperage
30 AMP
Motor Power Rating up to 5 hp
Operating Position
Non-positional mounting.
Universal Mounting Allows for easy installation. Unused portions
Bracket
of the bracket simply snap off with pliers.
Terminals
Screw or push-on. Adapters to convert
screw-on to push-on are provided.
Dimensions
1.75W x 2.25L x 1.50H
90X Series Potential Relays
• Meets all requirements of
OEM relays
• Universal break-off
bracket
Features/Benefits
• 50/60 cycle
• Contact rating 35 amp
@ 277 VAC
• Non-positional
• Instructions and wiring
diagram included in each
relay
®
903X Series General
Purpose Switching Relays
Double pole – double throw (DPDT)
Applications
• HVAC/ R
• Appliance vending machines
• Fan controls
• Business machines
PART
COIL TERMINAL TERMINAL CROSS REFERENCE
NO.
VOLTAGE 1-2-3
4-5-6 ESSEX/RBM HONEYWELL
90340
24
power
power
90-340
R8222D1014
90341 110/12 power
power
90-341
R4222D1013
90342 208/240 power
power
90-342
R4222N1021
CONTINUOUS
PART
COIL PICK-UP DROP OUT REPLACES GE 3ARR3
NO.
VOLTAGE MIN. MAX.
MAX.
RELAY GROUPS*
9063
170
139 153
55 2J; 2K; 2L; 2M; 5N; 7J; 7K; 7L; 7M; 7N; 8L;
8M; 8N
9064
395
260 275 120 3A; 3B; 3AV; 3AU; 4A; 4B; 6A; 6B; 6AV; 10A;
10B; 10AU; 10AV; 14A; 14B; 16A
9065
332
168 182
90 3P; 3R; 3AP; 5P; 5R; 5S; 5T; 13P; 19N; 22S
9066
395
215 225 120 3U; 3V; 3AT; 6U; 6V; 6W; 16U
9067
420
295 315 125 3C; 3D; 3AA; 4C; 4D; 4BK; 6C; 6D; 6AA; 10C;
10D; 26A; 26B; 26C; 26D
9068
502
325 345 135 3E; 3F; 3AB; 3AC; 4E; 4F; 4G; 6E; 6F; 6G; 10H;
10AB; 10AC; 26E; 26F; 26G; 26H; 27E; 27F; 27G
9069
336
180 195 105 3S; 3T; 10S; 10T; 10AS; 13S; 13T; 20S; 25S; 25T
9070
253
285 305
77 5B; 5C; 5D; 5AA; 8B; 8C; 8D; 27A; 27B; 27C
9071
420
212 232 121 6TV; 6TW; 10V; 16TV; 20V
• Accomodates screw-on or push-on connections.
• Dimensions identical to industry standard potential relays.
• Easy replacement mounting with universal mounting bracket.
• Start winding protection if motor does not start.
• Prevents start capacitor venting when motor doesn’t start.
®
Note: See Technical Area for Application Note on Relays
Applications
• Replaces all OEM potential relays
• Used on any single phase motor or
air conditioning and refrigeration
compressor up to 5 hp.