62
Applications
• Use on any single phase air conditioner or refrigeration unit
• Low voltage situations
• Hard starting compressors
Choosing the correct hard start for the application combines a technical need with a professional preference. Select from the broadest offering of hard
starts from the Pioneer of Hard Start technology.
Three (3) styles to choose from:
•
SPP Series
PTC/Capacitor combination
•
SPPE Elite Series
Electronic Potential Relay (EPR)/Capacitor combination
•
SK3W Series
3-wire Potential Relay/Capacitor combination
A/C Hard Starts
SK3W Series 3-wire Potential Relay/Capacitor Combination
Features/Benefits
• OEM-Style 3-wire Installation
• Instant re-start
SPPE ‘E Class’ Series EPR/Capacitor Combination
Features/Benefits
• Electronic Potential Relay Technology (EPR)
• Backup electronic timing circuit to protect
the compressor
• Voltage sensing
• Instant re-start
• Easy 2-wire installation
• Can be used on PSC and CSIR type
compressors
SPP Series PTC/
Capacitor Combination
Features/Benefits
• Positive Temperature Coefficient
Technology (PTC)
• Field proven reliability
• Easy 2 –wire installation
• Most economic
• Easy installation with “fast clamp-on” connection
• Models for standard and scroll compressors
• 330 VAC Start Capacity Voltage
®
OPERATING
PART
VOLTAGE RECOMMENDED INCREASE
NO.
(VAC)
RANGE (hp) IN TORQUE (%)
SPP*
90 – 277
½ to 10
250%
SPP5
90 – 277
½ to 10
300%
SPP6
90 – 277
½ to 10
500%
SPP7S
90 – 277
½ to 10
600%
* This model does not include a capacitor
®
DROP-OUT PICK-UP MAXIMUM START
PART
H.P.
VOLTAGE VOLTAGE
COIL
CAP
NO.
RATINGS COMPRESSOR (VAC)
(VAC)
VOLTAGE
(mF)
SK3W2 1 thru. 2 HP
Standard
60-135
204-233 500 VAC 88 - 108
SK3W3 2½ thru. 3 ½ HP Standard
60-121
171-184 420 VAC 189 - 227
SK3W5 4 thru. 5 HP
Standard
60-121
171-184 420 VAC 243 - 292
SK3W4S 3 thru. 4 HP
Scroll
60-135
204-233 500 VAC 189 - 227
SK3W6S 4½ thru. 6 HP
Scroll
60-121
171-184 420 VAC 270 - 324
AC Hard Starts
OPERATING
PART
VOLTAGE RECOMMENDED CAPACITOR
NO.
(VAC)
RANGE (hp)
Size (uF)
SPP4E
90 – 130
1/8 – 1
88–106
SPP5E
90 – 277
1/3 – 2
43–52
SPP6E
90 – 277
1/2 – 3
88–106
SPP7E
90 – 277
1 – 4
130–156
SPP8E
90 – 277
1 and up
189–227
SPP9E
90 – 277
1 and up
233–280
SPP10E
90 – 277
3 and up
270–324 / 330V
“Fast Clamp-On”
Connection
(used with SK3W Series)
S
K3W Series 3-wire
Application Note: 2-wire vs. 3-wire Installation
SPP & SPPE
Series 2-wire
Hard Start Comparison
SPPE SPP SK3W
Series Series Series
Start Sensing Technology
Voltage N/A Voltage
Uses Electronic Potential Relay (EPR)
Yes
No Yes
Instant Re-Start
Yes
No Yes
Senses Motor Start
Yes
No Yes
Two wire, non-polarized
Yes
Yes No
OEM Style, 3-wire
No
No Yes
Replaces 3-wire capacitor kit
Yes
Yes Yes
UL approved
Yes
Yes Pending
PTCR Device
No
Yes No
Backup Timing Safety Circuit
Yes
No No
Potentially damaging to motor windings No
No No
Requires non-replaceable fuse protection No
No No