Index of Footnotes
1 Item to be discontinued when stock is depleted
  2 Ball Bearing
  3 Special OEM replacement motor
  4 Supplied with lead and plug assembly
  5 $ Energy efficient two value capacitor start,
capacitor run motor
  6 60/50 HZ
  7 Resilient mounting rings included
  8 Nema design A
  9 Reversing plug
 10 Reversible. Quick connect terminals
 11 C Flange kit available
 12 303 Stainless steel shaft
 13 Six lead motor suitable for part winding start
 14 Totally enclosed non-ventilated
 15 56HZ = 7/8 keyed X 2 5/16 shaft
 16 $ E-Plus energy efficient motor complying with
EPact
 17 Suitable for 208 volts @ 1.0 service factor
 18 Includes 1/4 - 5/16 bushing
 19 C & D flange kit available
 20 $ Energy efficient capacitor start, capacitor run
Conservationist motor
 21 Terminal in bracket construction
 22 3 thru bolts, 4.42 dia. Bolt circle
 23 Suitable for 200/400 volt and 50 HZ
 24 Mounting accessories packaged with motor
 25 Has hex mounting hub on both ends for cradle base
mounting
 26 Extended thru bolts, shaft end only
 27 Extended thru bolts, both ends
 28 Blower kit adaptable, TEFC
 29 60 degree C ambient
 30 56,140 frame combination base (12 mounting holes)
 31 40 degree C ambient
 32 24” leads (minimum)
 33 Roller bearings
 34 Rigid base
 35 Quick connect design bracket
 36 Lug mount
 37 Lead reversible, no plug
 38 Includes conduit box, mounting screws, gasket,
shipped detached
 39 Gasketed conduit box
 40 Four mounting holes in shell
 41 Extended thru bolts, lead end only
 42 Eight mounting holes in shell
 43 Class A insulation
 44 CCWLE rotation only
 45 Capacitor start
 46 Adapt-a-Lug motors (See lugs)
 47 3/8 diameter shaft
 48 1.0 Service factor at 50 HZ
 49 1.0 Service factor
 50 Use with 5MFD/370V @ 230 volt, 7.5MFD/370 volt
@ 208 volt
 51 Use downsize 250 Frame C & D flange kits (D-flange
kit part # 800289-01, C-flange kit part # 800288-01
 52 Two-speed connection: white-common, red-low,
black-high
 53 Twelve lead, wye delta
 54 Triple build wire for greater high voltage insulation
 55 Terminal board
 56 TEAO gasketed conduit box - 3/4 extended thru bolts
 57 Tapped holes for Coleman mount
 58 Supplied with resilient mounting rings
 59 Suitable for use with low ambient speed control
 60 Stock no. 1218A adapter and rings supplied for base
mounting
 61 Start capacitor inside
 62 Split Phase
 63 Speck pump replacement motor
 64 Spade connector
 65 Six lead, Wye Delta
 66 Sealed switch design
 67 Rewire for second speed
 68 PSC motor
 69 Pin hole in shaft
 70 Permanent Split Capacitor
 71 No hubs on either end
 72 No brake kit available
 73 No base
 74 Nema design A available until current stock is
depleted, then will become Nema design B
 75 Mounting rings not included
 76 Motors shipped with thru bolts out shaft end - See
photos above. May be reversed for vertical
applications
 77 Molex Terminal Plug
 78 Moderate start torque
 79 Leadless design
 80 Large capacitor/terminal box construction
 81 Includes base
 82 Horizontal mount only
 83 Extended thru bolts - 5/8
 84 Energy efficient with split phase start, capacitor run
with mounted capacitor
 85 Energy efficient $ - capacitor start/run
 86 Cord and plug with pull chain
 87 Class F insulation
 88 C & D flange kit adaptable, ODP, EMI Series 850000
 89 60” leads
 90 50 degree C ambient
 91 5/8 extended thru bolts, 1 7/8 shaft length and 1/2
shaft dia.
 92 48/56 FR = 1/2 X 1 1/2 shaft with 5/8 shaft adapter
- 48/56 slotted 3 height base
 93 36” cord
 94 30” leads (minimum)
 95 3/8 flatted shaft
 96 2 thru bolts, 4.42 dia. Bolt circle
 97 182T and 184T mounting holes, 4.5 shaft height
 98 1/2 hub on shaft end and slinger
 99 1/2 extended thru bolts, shaft end
100 1/2 diameter shaft
101 1.5 service factor
102 1.15 service factor
103 When using U. E. base, add (2) 1221A adapter rings
to EACH mounting ring
104 Vertical mount
105 Use with 1805A or 2099A bracket
106 Use 4MFD/370V capacitor
107 Uprated - low service factor
108 Two-speed motor
109 Two side bosses
110 Two mounting holes in each bracket for a 9 and for a
10.18 bolt circle
111 Totally enclosed version of OCC1026
112 Totally enclosed fan cooled
113 Totally enclosed
114 Threaded shaft with Acme threads
115 This motor is rated for operation on 60 or 50 HZ
power, full load amps listed at 60 HZ
116 Temperature sensitive thermostat with two leads for
connection to external control
117 TEAO gasketed conduit box
118 TEAO
119 Suitable replacement for Aaon
120 Suitable replacement for 1/12 HP and 1/10 HP
121 Stronger 3/4 HP required for some applications
122 Stock number 91 has a stainless steel shaft and 20
leads for use on ice machines
123 Stock no. 684 BA dimension was 4, motors built
after 4/98 will have a BA dim. Of 3 3/4
124 Stainless steel shaft
125 Special pivot style rigid base
126 Special mounting bracket
127 Special Hayward replacement for SP-1515-Z24-EBK,
EBKC, C48M2A16A1
128 Special Doughboy replacement, less base, 40 degree
C ambient, Al. Windings
129 Special Canadian motor, external relay is required
130 Sleeve bearing
131 Single flat on shaft
132 Shaft sleeve and key supplied for 5/8 diameter
133 Shaft N-W = 2.50 with two flats .04 deep, 2.16 long,
90 degrees apart
134 Shaft N-W = 2.50 with 5/8 diameter and keyway
135 Shaft has no flat
136 Shaft dim.= 9 X 1/2 X 8 1/2
137 Shaft dim.= 8-1/2 X 1/2 X 9 1/8
138 Shaft dim. = 9 X 1/2 X 7-1/2
139 Shaft dim. = 10-3/4 X 1/2 X 10-15/16
140 Shaft diameter is 1/2, N=2
141 Shaft diameter is 1/2, N=1.94 with .04 deep flat
142 Service factor amps
143 Service factor 1.00 under inverter power (sine wave
power only 60 HZ) as shown above
144 Service factor 1.0 used on non-sinusoidal voltage
wave forms
145 Run capacitor mounted on motor shell
146 Round frame
147 Resilient mounting rings included for refrigeration
applications
148 Replacement for Carrier HD52AK652
149 Reconnect for separate speeds
150 Rated 50/60 HZ
151 Quick connect design bracket, auto overload protector
152 Pump series: L
153 Pump series: C
154 Previous stock numbers with X suffix are the same
as current models
155 Polaris Vac-sweep (shaft adapter not required)
156 Open shaft end bracket
157 Open construction
158 Open motor construction, overload protector
mounted at 12 O’clock
159 Open dripproof
160 Non-reversible, connected for CW facing end
opposite shaft
161 No side bosses
162 No resilient rings. 12 leads with Molex terminal
163 No keyway, double flat
164 No hub on lead end end frame
165 No extended thru bolts
166 No conduit box
167 New Quad-Plus model - removable base (RMOV),
vertical shaft up or down and steel frame
construction
168 Nema 42/48 C-face, 1/2 diameter keyed shaft, 1
5/16 long
169 Motors produced before June, 2003 are E+
170 Motors may be rewired to run CW
171 Motor is thermally protected
172 Motor is center mounted
173 Motor has 4 studs
174 Motor fits torque mount
175 Molex lead connection plug, 12 long leads
176 Moisture proof stator
177 Meets the requirements of the energy policy act of
1992
178 Low speed 1/2 HP
179 Low amps
180 Low amp replacement for a variety of OEM Special
and SPL 5 horsepower requirements
181 Loose lead construction
182 Locked bearing on drive end
183 Lifting provisions
184 Lead exit is on shaft end
185 Items with Universal and A. O. Smith stock numbers
and same specifications are identical. The A. O.
Smith stock numbers will be discontinued when
stock is depleted.
186 Item to be discontinued when stock is depleted.
Discontinued items available form Graham
Transmission, Inc.
187 Incudes mounting bracket and shaft bushing
188 Includes split bushing and key for 5/8 shafts. 3 thru
bolts on a 4.42 dia. Bolt circle
189 Includes split bushing and key for 5/8 shafts
190 Includes pilot light detector
191 Includes mounting bracket
192 Includes four (4) 10-32 mounting holes
193 Includes former GE brand equipment
194 Includes fan blade
195 Includes 6’ cord and switch
196 Includes 5/8 adapter and key
No. Footnote Description
No. Footnote Description
No. Footnote Description
1,2,3,4,5,6,7 9,10,11,12,13,14,15,16,17,18,...324