151
Infrared Thermometers
Laser Infrared Thermometers offer precise, non-contact measurement in a
lightweight, hand held instrument. With one hand operation, they are ideal
for a wide variety of applications.
PIT1
• 1:1 Optical Ratio
• Pocket Size
• Min/Max Measurements
LIT6
• 6:1 Optical Ratio
• Laser Pointer
• Backlight
LIT8B
• 8:1 Optical Ratio
• Laser Pointer
• Trigger Style
• Backlight
LIT50
• 50:1 Optical Ratio
• Laser Pointer
• High & Low Temperature Range
• Backlight
• Carrying Case Included
LIT11TC
11:1 Optical Ratio
• Laser Pointer
• High & Low Temperature Range
• Backlight
• Carrying Case Included
• K-Type Thermocouple (probe included)
-
Temperature Range 58°F to 482°F
(14°C to 250°C)
Full range:
-83.2°F to 1999°F
(-64°C to 1400°C)
- Temperature Accuracy +/- 1% of reading or 2°F
• Circuit Breaker Panels
• Motors/Bearings
• Transformers
Applications
• Refrigeration Systems
• Heating Systems
• Supply and Return Registers
Meters
PIT1
LIT6
LIT8B
LIT11TC
LIT50
Optical Ratio
1:1
6:1
8:1
11:1
50:1
Temperature Range -27°F to +428°F
0°F to +500°F
-4°F to 518°F
-76 °F to 932°F
-58°F to 1832°F
(-33°C to +220°C)
(-18°C to +260°C)
(-20°C to 270°C)
(-60°C to 500°C)
(-50°C to 1000°C)
Best Resolution
0.1°C or °F
1°F (1°C)
1°F (1°C)
0.1°F
0.1°F
Accuracy
+2% of reading or
+2% of reading or
+2% of reading or
+/- 2°F
+/- 2% of reading or
+2°C
+2°C
+4°F (2°C)
(+/- 1°C)
+4°F (2°C)
Emissivity
0.95 adjustable
0.95 fixed
0.95 fixed
0.95 adjustable
0.95 fixed
Automatic shut off
Yes
Yes
Yes
Yes
Yes
Power Supply
CR2032
9V Battery
9V Battery
2 AA Batteries
9 V Battery
(Included)
(Not Included)
(Included)
(Included)
(Included)
Weight
1.3 oz. (32g)
5.3 oz. (150g)
5.8 oz. (180g)
6.3 oz. (179g)
10.23 oz. (290g)
Dimensions
.7" X 1.5" X 2.7"
5.1” X 2” X 1.25”
6.4" X 3.2" X 2.4"
6.9” X 1.5” X 2.8”
3.94” X 2.2” X 9.06”
(18mm X 37mm X 68mm) (18mm X 50mm X 42mm) (159mm X 79mm X 57mm)
(175 X 39 X 71mm)
(100 X 56 X 230 mm)
Emissivity:
The ability of a surface to reflect the infrared radiation relative to an ideal
surface. A flat black surface is as close to ideal as you can get. Most
infrared thermometers have a fixed emissivity of .95. The more reflective
the surface the lower the emissivity adjustment should be.
NEW
Application Note:
What is Distance to Spot Ratio (D:S)?
This is the size of the measurement field that a non-contact infrared
thermometer uses to provide a temperature reading. The infrared
thermometer averages the temperature of that field to calculate the
temperature reading. For example, a D:S ratio of 8:1 means that the
measurement field measures approximately 1 foot in diameter when
the target is approximately 8 feet away.
• Ducts
• And More
Infrared Specifications
1...,158,159,160,161,162,163,164,165,166,167 169,170,171,172,173,174,175,176,177,178,...214