117
Universal Thermostats
General Purpose L & LD Series
• Open on rise
• Close when temperature differential is reached
• 1/4" quick disconnect terminals
• Use 60T Electrical Ratings
Applications
• Most home laundry dryers
• Fan and Limit Applications
UL RECOGNIZED
“L” Series,
Single Pole - Single Throw
36T Electrical Ratings
Motor Rating
Resistive
(Inductive)
Pilot
VAC (Non-Inductive)
Full Load Locked Rotor
Duty
120
15A
3A
12A
125 VA
240
1OA
1.5A
6A
125 VA
350°F Max Ambient Temperature
60T Electrical Ratings
Motor Rating
Resistive
(Inductive)
Pilot
VAC (Non-Inductive)
Full Load Locked Rotor
Duty
120
25.OA
14.OA
72.OA
125 VA
240
25.OA
10.OA
60.OA
125 VA
350°F Max Ambient Temperature
Typical Electrical Ratings
Supco
No.
°Diff.
Open (°F) Close (°F)
L120
10
120
110
L125
10
125
115
L130
15
130
115
L135
15
135
120
L140
20
140
120
L145
20
145
125
L150
20
150
130
L155
20
155
135
L160
20
160
140
L165
20
165
145
L170
20
170
150
L175
20
175
155
L180-20 20
180
160
L180-40 40
180
140
L190
40
190
150
L200
40
200
160
L205
40
205
165
L225
40
225
185
L240
40
240
200
L250
40
250
210
L260
40
260
220
L270
40
270
230
L290
40
290
250
L300
40
300
260
L320
40
320
280
L340
40
340
300
Supco No. Cut Out °F Cut In °F Differential °F
LD120
120
105
15
LD130
130
115
15
LD135
135
120
15
LD140
140
120
20
LD145
145
125
20
LD155
155
135
20
LD170
170
150
20
LD190
190
170
20
LD200
200
160
40
LD210
210
170
40
LD225
225
185
40
LD240
240
200
40
LD270
270
230
40
LD290
290
250
40
LD305
305
265
40