Thermally protected
UL recognized
CSA or ULc certified
NOTE:
Rotation is determined by looking at shaft end. Shaft length is measured from motor face.
61
69 to 75 Free Air Output
Centrifugal Blowers
CFM AT STATIC PRESSURE SHOWN
STATIC PRESSURE (INCHES OF WATER)
NAMEPLATE CFM VOLTS
FREQ.
NO. OF
SPEEDS RPM@ FREE AIR AMPS@ FREE AIR BRNG.
MODEL
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
A069
72 67 63 60 53 52 50 43 40 –
69
208-230
60
1
3000
0.45
SLV
B23617
72 67 64 62 57 55 50 46 41 33
70
115/230
60
1
3000
.9/.45
SLV
B23618
72 67 64 62 57 55 50 46 41 33
70
115/208-230 60
1
3000
.95/.45
BALL
A071
70 67 63 58 57 55 51 35 – –
71
115
60
1
2850
0.7
SLV
A073
72 69 67 63 61 57 53 48 43 37
73
115 - 230 50/60
1
3200
.7/.35
BALL
B75
68 63 57 47 34 14 – – – –
75
115
60
1
3200
0.59
SLV
A075
73 69 65 62 58 55 50 45 40 35
75
230
60
1
3200
0.4
BALL
A082
66 62 53 52 47 42 23 – – –
75
115
60
1
2800
0.95
SLV
A069
B23617
A071
A073
B75
A075
A082
B23618
1...,51,52,53,54,55,56,57,58,59,60 62,63,64,65,66,67,68,69,70,71,...184