Thermally protected
UL recognized
CSA or ULc certified
NOTE:
Rotation is determined by looking at shaft end. Shaft length is measured from motor face.
35
Replacement Models
OEM DIRECT
Fan Coil Air-Conditioning and Heating Unit Motors
5.0” Diameter
NEW ITEM! See page 113 for a complete listing of all our new products.
FASCO
MODEL
TYPE
HP
VOLTS RPM SPD.
AMPS
ENCLOSURE ROT. BRNG.
SHAFT DIM.
“A”
DIM.
FIG.
NOTES
D249 SP
1/50 - 1/80 - 1/160
115 1050 3
1.1-.6-.4
Open Vent. DS SLV 7 5/8 X 3/8 X 7 5/8 2 5/8 A 147
D255 SP
1/25 - 1/50 - 1/80
115 1050 3
1.5-1-.6
Open Vent. DS SLV 7 1/2 X 1/2 X 7 1/2 3 1/4 A 147
D250 SP
1/25 - 1/50 - 1/80
115 1050 3
1.5-1-.6
Open Vent. DS SLV
8 X 3/8 X 8
3 1/4 A 147
D655 SP
1/25 - 1/40 - 1/70
230 1050 3
.7-.5-.3
Open Vent. DS SLV 10 X 1/2 X 10 3 1/4 A 147
D252 SP
1/20 - 1/40 - 1/70
115 1050 3
1.6-.8-.5
Open Vent. DS SLV 7 1/2 X 3/8 X 7 1/2 2 5/8 A 147
D253 SP
1/20 - 1/40 - 1/50
115 1050 3
2.2-1.4-.8
Open Vent. DS SLV 7 1/2 X 1/2 X 7 1/2 2 5/8 A
D254 SP
1/15 - 1/30 - 1/50
115 1050 3
2.1-1.3-.8
Open Vent. DS SLV
8 X 3/8 X 8
3 1/4 A 147
D251 SP
1/15 - 1/35 - 1/50
208-230 1050 3
1.2-.5-.4
Open Vent. DS SLV 9 1/4 X 1/2 X 8 1/2 2 5/8 B
D257 SP
1/15 - 1/20 - 1/25
277 1050 3
1.1-.7-.6
Totally Encl. DS SLV
9 X 1/2 X 9
3 1/4 C 147
D389 SP 1/15 - 1/20 - 1/30 - 1/50
115 1050 4 2.4-1.6-1.1-.8 Open Vent. DS SLV 10 1/4 X 1/2 X 10 1/4 3 1/8 A 147
D256 SP
1/10 - 1/20 - 1/30
115 1050 3
3.4-1.7-1
Open Vent. DS SLV
8 X 1/2 X 8
3 7/8 A 147
D293 SP 1/10 - 1/30 - 1/40 - 1/45 - 1/50 115 1050 5 3.6-1.6-1.2-.8-.6 Open Vent. DS SLV 10 3/4 X 3/8 X 10 3/4 3 1/4 B
D289 SP 1/10 - 1/30 - 1/40 - 1/45 - 1/50 115 1050 5 3.6-1.6-1.2-.8-.6 Open Vent. DS SLV 10 3/4 X 1/2 X 10 3/4 3 1/4 B
D224 SP
1/6 - 1/8 - 1/12
230 1050 3
3.2-2.3-1.8 Open Vent. DS SLV 10 X 1/2 X 10
A 147
D290 PSC 1/10 - 1/15 - 1/25 - 1/40
115 1050 4 2.2-1.4-1-.7 Open Vent. REV SLV
1/2 X 8 1/2
3 1/4 D 29, 128,
D291 PSC 1/10 - 1/15 - 1/25 - 1/40
115 1050 4 2.2-1.4-1-.7 Open Vent. DS SLV 10 3/4 X 1/2 X 10 3/4 3 1/4 E
D294 PSC 1/10 - 1/20 - 1/25 - 1/35 - 1/50 115 1050 5 1.3-1-.7-.6-.5 Open Vent. DS SLV 10 3/4 X 3/8 X 10 3/4 3 1/4 E
D292 PSC 1/10 - 1/15 - 1/25 - 1/35 208-230 1050 4
1-.7-.4-.3
Open Vent. DS SLV 10 3/4 X 1/2 X 10 3/4 3 1/4 E
D277 PSC
1/10 - 1/12 - 1/20
277 1050 3
.7-.5-.4
Open Vent. DS SLV 8 1/2 X 1/2 X 8 1/2 3 7/8 F 29, 147
D1005 PSC
1/10
460 1075 2
0.5
Open Vent. DS SLV 9 5/8 X 1/2 X 9 5/8 3 1/3 B
D354 PSC
1/6 - 1/10 - 1/20
115 1050 3
2.8-1.8-1
Open Vent. DS SLV 8 1/2 X 1/2 X 8 1/2 3 7/8 F 53, 147
D245 PSC
1/3 - 1/5
230 1050 2
2.9-1.7
Open Vent. DS SLV
8 X 1/2 X 8
4 1/2 G 53, 147
D221 PSC 1/6 - 1/8 - 1/10 - 1/12
115 1550 4 3.2-1.7-1.3-1 Open Vent. DS SLV
8 X 1/2 X 8
3 5/8 G
D382 PSC
1/25 - 1/40 - 1/50
115 1550 3
.6-.4-.3
Open Vent. DS SLV 6 7/8 X 1/2 X 6 7/8 3 G 54, 147
D1050 PSC
1/8
230 1550 1
1.1
Open Vent. CW SLV
1/2 X 3
3 1/4 H 147, 199
D347 PSC 1/8 - 1/10 - 1/15 - 1/20
115 1550 4 2.3-1.6-1.2-.7 Open Vent. DS SLV 10 1/2 X 1/2 X 10 1/2 3 I
29
D247 PSC
1/6 - 1/8 - 1/12
230 1550 3
1-.7-.5
Open Vent. DS SLV
8 X 1/2 X 8
3 7/8 A 29, 147
D258 PSC
1/5 - 1/10
208-230 1550 2
2.8-1.3
Open Vent. DS SLV
8 X 1/2 X 8
3 3/8 F 54, 147
D1025 PSC
1/3
208-230 1625 1
2.3
Open Vent. DS SLV 7 1/8 X 1/2 X 7 1/4 4 1/8 A 54
FIG. A
D249, D255, D250,
D655, D252, D253, D254, D389,
D256, D224, D247, D1025
FIG. B
D251, D293, D289,
D1005
FIG. C
D257
FIG. D
D290
FIG. E
D291, D294, D292
FIG. F
D277, D354, D258
FIG. G
D245, D221, D382
FIG. H
D1050
FIG. I
D347
NOTES
:
29:
4M 370V capacitor included
53:
4M 370 capacitor included
54:
5M 370V capacitor included
128:
Electrically Reversible
147:
COMES WITH 2 1/2” O.D. RUBBER MOUNTING RINGS
199:
Original motor is SP, D1050 is PSC to provide greater motor efficiency and permit
closing shaft end of motor to prevent moisture from entering motor
1...,25,26,27,28,29,30,31,32,33,34 36,37,38,39,40,41,42,43,44,45,...184