240
Century® and Century® Industrial Brake Motors
Single and Three Phase – Dripproof and TENV – 1/4 thru 2 HP
Features:
• Rigid Base
• Ball Bearing
• 60 Hz
• 40°C Ambient
• Class B or F Insulation • NEMA “C” Bracket
• Stearns
®
or Dings Brakes – choice of brand supplied is reserved to A. O. Smith
Applications:
Overhead doors, vertical conveyors, hoists, etc. in which motor and connected load must be stopped and held in controlled positions.
Full Load
Service
Stock Insulation
“C”
HP
RPM
Volts
Amps
Factor
Frame Number
Class Brake
Dim.
Notes
Single Phase – TENV Capacitor Start – “C” Bracket
1⁄4
1800
115/208-230
3.8/2.0-1.9
1.00
56C
C540
B
3 ft. lb.
15.0
1
1⁄3
1800
115/208-230
5.2/2.5-2.6
1.00
56C
C541
B
3 ft. lb.
15.0
1
Three Phase – TENV – “C” Bracket
1⁄3
1800
208-230/460
1.2-1.2/.60
1.00
56C
H861
J
B
3 ft. lb.
14.1
1
1⁄2
1800
208-230/460
1.6-1.8/.90
1.00
56C
H862
J
B
3 ft. lb.
14.1
1
575
0.7
1.00
56C
H863
B
3 ft. Ib.
14.1
259
3⁄4
1800
208-230/460
2.1-2.4/1.2
1.00
56C
H865
J
B
6 ft. Ib.
14.5
1
575
0.8
1.00
56C
H866
B
6 ft. Ib.
15.0
1,259
Three Phase – TENV Dripproof – “C” Bracket
1⁄2
1800
208-230/460
1.9-2.2/1.1
1.25
56C
H522
J
B
3 ft. Ib.
13.7
1
3⁄4
1800
208-230/460
2.5-2.6/1.3
1.25
56C
H594
J
B
6 ft. lb.
14.0
1
1
1800
208-230/460
3.4-3.4/1.7
1.25
56C
H687
J
B
6 ft. lb.
15.0
1
208-230/460
3.4-3.4/1.7
1.25
143TC
R165
J
B
6 ft. lb.
15.8
1
1-1⁄2
1800
208-230/460
4.8-5.0/2.5
1.20
56C
H695
J
B 10 ft. lb.
15.3
1
Notes:
1. Item to be discontined when stock is depleted
259. 575 volt brake coil
R167
Century®
Motors specially designed, tested and warranted to be
Corona-
Free
for compatible inverter duty are marked on this page with a
J
See page 4 and 5 of this catalog for more Speed Engineered
®
motors information.